------------ IPMI Sensor Data ----------------

BMC_HEALTH       | 0x0        | discrete   | 0x0000| na        | na        | na        | na        | na        | na        
VERSION_CHANGE   | 0x0        | discrete   | 0x0000| na        | na        | na        | na        | na        | na        
BMC_WATCHDOG     | 0x0        | discrete   | 0x0000| na        | na        | na        | na        | na        | na        
ACPI_STATE       | 0x0        | discrete   | 0x0100| na        | na        | na        | na        | na        | na        
PROC_STATE       | 0x0        | discrete   | 0x0000| na        | na        | na        | na        | na        | na        
SYSTEM_RESET     | 0x0        | discrete   | 0x8000| na        | na        | na        | na        | na        | na        
FW_PROGRESS      | 0x0        | discrete   | 0x0000| na        | na        | na        | na        | na        | na        
PCIE_CR_INT      | 0x0        | discrete   | 0x0000| na        | na        | na        | na        | na        | na        
INTEGRITY        | 0x0        | discrete   | 0x0000| na        | na        | na        | na        | na        | na        
BIOS_POST        | 0x0        | discrete   | 0x0000| na        | na        | na        | na        | na        | na        
BOARD-POWER      | 80.000     | Watts      | ok    | na        | na        | na        | na        | na        | na        
PAY_12-VOL       | 12.000     | Volts      | ok    | na        | 10.752    | na        | na        | 13.248    | na        
PAY_5_0-VOL      | 5.072      | Volts      | ok    | na        | 4.655     | na        | na        | 5.361     | na        
PAY_5_0_SB-VOL   | 5.040      | Volts      | ok    | na        | 4.655     | na        | na        | 5.361     | na        
PAY_3_3-VOL      | 3.302      | Volts      | ok    | na        | 3.061     | na        | na        | 3.519     | na        
PAY_3_3_SB-VOL   | 3.302      | Volts      | ok    | na        | 3.061     | na        | na        | 3.519     | na        
BAT_3_0-VOL      | 3.109      | Volts      | ok    | na        | 1.928     | na        | na        | 3.254     | na        
PCH_1_8_SB-VOL   | 1.808      | Volts      | ok    | na        | 1.712     | na        | na        | 1.880     | na        
CPU_VCCIN-VOL    | 1.784      | Volts      | ok    | na        | 1.448     | na        | na        | 2.040     | na        
PVDDQ_ABC-VOL    | 1.224      | Volts      | ok    | na        | 1.112     | na        | na        | 1.304     | na        
PVDDQ_DEF-VOL    | 1.216      | Volts      | ok    | na        | 1.112     | na        | na        | 1.304     | na        
BMC_1_15_SB-VOL  | 1.157      | Volts      | ok    | na        | 1.044     | na        | na        | 1.257     | na        
PCH_1_05_SB-VOL  | 1.064      | Volts      | ok    | na        | 0.960     | na        | na        | 1.136     | na        
CPU_VCCIO-VOL    | 1.016      | Volts      | ok    | na        | 0.904     | na        | na        | 1.096     | na        
PCH_VNN_SB-VOL   | 1.008      | Volts      | ok    | na        | 0.904     | na        | na        | 1.096     | na        
CPU_VCCSA-VOL    | 0.896      | Volts      | ok    | na        | 0.456     | na        | na        | 1.152     | na        
INLET-TMP        | 32.000     | degrees C  | ok    | na        | na        | na        | 60.000    | 75.000    | 100.000   
OUTLET-TMP       | 49.000     | degrees C  | ok    | na        | na        | na        | 65.000    | 75.000    | na        
CPU-TMP          | 63.000     | degrees C  | ok    | na        | na        | na        | 90.000    | 105.000   | na        
HWM-TMP          | 36.000     | degrees C  | ok    | na        | na        | na        | 60.000    | 70.000    | 80.000    
PCH-TMP          | 65.000     | degrees C  | ok    | na        | na        | na        | 90.000    | 100.000   | na        
CPU-DIMMA_1-TMP  | 37.000     | degrees C  | ok    | na        | na        | na        | 85.000    | 95.000    | na        
CPU-DIMMB_1-TMP  | 35.000     | degrees C  | ok    | na        | na        | na        | 85.000    | 95.000    | na        
CPU-DIMMD_1-TMP  | 37.000     | degrees C  | ok    | na        | na        | na        | 85.000    | 95.000    | na        
CPU-DIMME_1-TMP  | 36.000     | degrees C  | ok    | na        | na        | na        | 85.000    | 95.000    | na        
FAN1-SPEED       | 5900.000   | RPM        | ok    | na        | 1200.000  | na        | na        | na        | na        
FAN2-SPEED       | 6000.000   | RPM        | ok    | na        | 1200.000  | na        | na        | na        | na        
FAN3-SPEED       | 6000.000   | RPM        | ok    | na        | 1200.000  | na        | na        | na        | na        
PSU1             | 0x0        | discrete   | 0x0100| na        | na        | na        | na        | na        | na        
PSU2             | 0x0        | discrete   | 0x0100| na        | na        | na        | na        | na        | na        
PSU1_INTAKE-TMP  | 42.000     | degrees C  | ok    | na        | na        | na        | 65.000    | 75.000    | 85.000    
PSU1_HOTSPOT-TMP | 44.000     | degrees C  | ok    | na        | na        | na        | 90.000    | 100.000   | 110.000   
PSU1_IN-VOL      | 240.000    | Volts      | ok    | na        | 90.000    | na        | na        | 264.000   | na        
PSU1_OUT-VOL     | 12.100     | Volts      | ok    | na        | 11.500    | na        | na        | 12.800    | na        
PSU1_IN-CUR      | 0.250      | Amps       | ok    | na        | na        | na        | na        | 18.000    | na        
PSU1_OUT-CUR     | 3.000      | Amps       | ok    | na        | na        | na        | na        | 166.000   | na        
PSU1_IN-POWER    | 60.000     | Watts      | ok    | na        | na        | na        | na        | 2000.000  | na        
PSU1_OUT-POWER   | 30.000     | Watts      | ok    | na        | na        | na        | na        | 2000.000  | na        
PSU1_FAN-SPEED   | 1950.000   | RPM        | ok    | na        | 450.000   | na        | na        | na        | na        
PSU2_INTAKE-TMP  | 37.000     | degrees C  | ok    | na        | na        | na        | 65.000    | 75.000    | 85.000    
PSU2_HOTSPOT-TMP | 36.000     | degrees C  | ok    | na        | na        | na        | 90.000    | 100.000   | 110.000   
PSU2_IN-VOL      | 240.000    | Volts      | ok    | na        | 90.000    | na        | na        | 264.000   | na        
PSU2_OUT-VOL     | 12.100     | Volts      | ok    | na        | 11.500    | na        | na        | 12.800    | na        
PSU2_IN-CUR      | 0.250      | Amps       | ok    | na        | na        | na        | na        | 18.000    | na        
PSU2_OUT-CUR     | 3.000      | Amps       | ok    | na        | na        | na        | na        | 166.000   | na        
PSU2_IN-POWER    | 60.000     | Watts      | ok    | na        | na        | na        | na        | 2000.000  | na        
PSU2_OUT-POWER   | 40.000     | Watts      | ok    | na        | na        | na        | na        | 2000.000  | na        
PSU2_FAN-SPEED   | 1650.000   | RPM        | ok    | na        | 450.000   | na        | na        | na        | na        

------------ IPMI Event Log Data Data ----------------

   1 | 10/13/2025 | 17:21:38 | System Boot Initiated #0x06 | System Restart | Asserted
   2 | 10/13/2025 | 17:24:18 | System ACPI Power State #0x04 | S5/G2: soft-off | Asserted
   3 | 10/13/2025 | 17:25:43 | Power Supply #0x2d | Power Supply AC lost | Asserted
   4 | 10/13/2025 | 17:25:43 | Power Supply #0x2e | Power Supply AC lost | Asserted
   5 |  Pre-Init  |0000000010| Unknown #0x0c |  | Asserted
   6 |  Pre-Init  |0000000013| System Boot Initiated #0x06 | Initiated by power up | Asserted
   7 |  Pre-Init  |0000000016| System Boot Initiated #0x06 | System Restart | Asserted
   8 |  Pre-Init  |0000000037| System Event | Timestamp Clock Sync | Asserted
   9 | 06/09/2026 | 08:44:27 | System Event | Timestamp Clock Sync | Asserted
   a | 06/09/2026 | 08:45:00 | Power Supply #0x2d | Power Supply AC lost | Asserted
   b |  Pre-Init  |0000000010| Unknown #0x0c |  | Asserted
   c |  Pre-Init  |0000000013| System Boot Initiated #0x06 | Initiated by power up | Asserted
   d |  Pre-Init  |0000000016| System Boot Initiated #0x06 | System Restart | Asserted
   e |  Pre-Init  |0000000019| System Event | Timestamp Clock Sync | Asserted
   f | 06/09/2026 | 09:11:01 | System Event | Timestamp Clock Sync | Asserted
  10 | 06/09/2026 | 09:48:43 | Power Supply #0x2d | Power Supply AC lost | Asserted
  11 |  Pre-Init  |0000000012| Unknown #0x0c |  | Asserted
  12 |  Pre-Init  |0000000015| System Boot Initiated #0x06 | Initiated by power up | Asserted
  13 |  Pre-Init  |0000000018| System Boot Initiated #0x06 | System Restart | Asserted
  14 |  Pre-Init  |0000000021| System Event | Timestamp Clock Sync | Asserted
  15 | 06/09/2026 | 11:56:56 | System Event | Timestamp Clock Sync | Asserted
  16 | 06/18/2026 | 12:30:44 | Power Supply #0x2e | Power Supply AC lost | Asserted
  17 |  Pre-Init  |0000000010| Unknown #0x0c |  | Asserted
  18 |  Pre-Init  |0000000013| System Boot Initiated #0x06 | Initiated by power up | Asserted
  19 |  Pre-Init  |0000000016| System Boot Initiated #0x06 | System Restart | Asserted
  1a |  Pre-Init  |0000000019| System Event | Timestamp Clock Sync | Asserted
  1b | 06/18/2026 | 12:31:34 | System Event | Timestamp Clock Sync | Asserted
  1c |  Pre-Init  |0000000010| Unknown #0x0c |  | Asserted
  1d |  Pre-Init  |0000000014| System Boot Initiated #0x06 | Initiated by power up | Asserted
  1e |  Pre-Init  |0000000017| System Boot Initiated #0x06 | System Restart | Asserted
  1f |  Pre-Init  |0000000020| System Event | Timestamp Clock Sync | Asserted
  20 | 08/12/2026 | 11:39:57 | System Event | Timestamp Clock Sync | Asserted
  21 |  Pre-Init  |0000000011| Unknown #0x0c |  | Asserted
  22 |  Pre-Init  |0000000014| System Boot Initiated #0x06 | Initiated by power up | Asserted
  23 |  Pre-Init  |0000000017| System Boot Initiated #0x06 | System Restart | Asserted
  24 |  Pre-Init  |0000000020| System Event | Timestamp Clock Sync | Asserted
  25 | 08/12/2026 | 13:26:10 | System Event | Timestamp Clock Sync | Asserted
  26 | 08/12/2026 | 14:33:15 | System ACPI Power State #0x04 | S5/G2: soft-off | Asserted
  27 | 08/12/2026 | 14:33:15 | Power Supply #0x2d | Power Supply AC lost | Asserted
  28 | 08/12/2026 | 14:33:15 | Power Supply #0x2e | Power Supply AC lost | Asserted
  29 |  Pre-Init  |0000000010| Unknown #0x0c |  | Asserted
  2a |  Pre-Init  |0000000013| System Boot Initiated #0x06 | Initiated by power up | Asserted
  2b |  Pre-Init  |0000000016| System Boot Initiated #0x06 | System Restart | Asserted
  2c |  Pre-Init  |0000000019| System Event | Timestamp Clock Sync | Asserted
  2d | 08/12/2026 | 14:33:48 | System Event | Timestamp Clock Sync | Asserted
  2e |  Pre-Init  |0000000010| Unknown #0x0c |  | Asserted
  2f |  Pre-Init  |0000000014| System Boot Initiated #0x06 | Initiated by power up | Asserted
  30 |  Pre-Init  |0000000017| System Boot Initiated #0x06 | System Restart | Asserted
  31 |  Pre-Init  |0000000020| System Event | Timestamp Clock Sync | Asserted
  32 | 08/17/2026 | 13:28:05 | System Event | Timestamp Clock Sync | Asserted
  33 |  Pre-Init  |0000000013| Unknown #0x0c |  | Asserted
  34 |  Pre-Init  |0000000016| System Boot Initiated #0x06 | Initiated by power up | Asserted
  35 |  Pre-Init  |0000000019| System Boot Initiated #0x06 | System Restart | Asserted
  36 |  Pre-Init  |0000000022| System Event | Timestamp Clock Sync | Asserted
  37 | 08/17/2026 | 13:33:28 | System Event | Timestamp Clock Sync | Asserted
  38 |  Pre-Init  |0000000011| Unknown #0x0c |  | Asserted
  39 |  Pre-Init  |0000000014| System Boot Initiated #0x06 | Initiated by power up | Asserted
  3a |  Pre-Init  |0000000017| System Boot Initiated #0x06 | System Restart | Asserted
  3b |  Pre-Init  |0000000021| System Event | Timestamp Clock Sync | Asserted
  3c | 08/17/2026 | 13:43:56 | System Event | Timestamp Clock Sync | Asserted
  3d |  Pre-Init  |0000000010| Unknown #0x0c |  | Asserted
  3e |  Pre-Init  |0000000013| System Boot Initiated #0x06 | Initiated by power up | Asserted
  3f |  Pre-Init  |0000000016| System Boot Initiated #0x06 | System Restart | Asserted
  40 |  Pre-Init  |0000000019| System Event | Timestamp Clock Sync | Asserted
  41 | 08/20/2026 | 09:53:03 | System Event | Timestamp Clock Sync | Asserted
  42 |  Pre-Init  |0000000011| Unknown #0x0c |  | Asserted
  43 |  Pre-Init  |0000000014| System Boot Initiated #0x06 | Initiated by power up | Asserted
  44 |  Pre-Init  |0000000017| System Boot Initiated #0x06 | System Restart | Asserted
  45 |  Pre-Init  |0000000020| System Event | Timestamp Clock Sync | Asserted
  46 | 09/04/2026 | 07:54:50 | System Event | Timestamp Clock Sync | Asserted
  47 |  Pre-Init  |0000000013| Unknown #0x0c |  | Asserted
  48 |  Pre-Init  |0000000016| System Boot Initiated #0x06 | Initiated by power up | Asserted
  49 |  Pre-Init  |0000000019| System Boot Initiated #0x06 | System Restart | Asserted
  4a |  Pre-Init  |0000000022| System Event | Timestamp Clock Sync | Asserted
  4b | 09/04/2026 | 07:57:39 | System Event | Timestamp Clock Sync | Asserted
  4c |  Pre-Init  |0000000011| Unknown #0x0c |  | Asserted
  4d |  Pre-Init  |0000000014| System Boot Initiated #0x06 | Initiated by power up | Asserted
  4e |  Pre-Init  |0000000017| System Boot Initiated #0x06 | System Restart | Asserted
  4f |  Pre-Init  |0000000037| System Event | Timestamp Clock Sync | Asserted
  50 | 09/17/2026 | 13:21:20 | System Event | Timestamp Clock Sync | Asserted
  51 |  Pre-Init  |0000000010| Unknown #0x0c |  | Asserted
  52 |  Pre-Init  |0000000013| System Boot Initiated #0x06 | Initiated by power up | Asserted
  53 |  Pre-Init  |0000000016| System Boot Initiated #0x06 | System Restart | Asserted
  54 |  Pre-Init  |0000000019| System Event | Timestamp Clock Sync | Asserted
  55 | 09/28/2026 | 05:51:58 | System Event | Timestamp Clock Sync | Asserted
  56 |  Pre-Init  |0000000014| Unknown #0x0c |  | Asserted
  57 |  Pre-Init  |0000000017| System Boot Initiated #0x06 | Initiated by power up | Asserted
  58 |  Pre-Init  |0000000020| System Boot Initiated #0x06 | System Restart | Asserted
  59 |  Pre-Init  |0000000023| System Event | Timestamp Clock Sync | Asserted
  5a | 09/28/2026 | 05:53:43 | System Event | Timestamp Clock Sync | Asserted
  5b |  Pre-Init  |0000000011| Unknown #0x0c |  | Asserted
  5c |  Pre-Init  |0000000014| System Boot Initiated #0x06 | Initiated by power up | Asserted
  5d |  Pre-Init  |0000000017| System Boot Initiated #0x06 | System Restart | Asserted
  5e |  Pre-Init  |0000000020| System Event | Timestamp Clock Sync | Asserted
  5f | 09/28/2026 | 05:59:32 | System Event | Timestamp Clock Sync | Asserted

------------  /usr/bin/ipmitool -V ----------------

ipmitool version 1.8.18

------------  /usr/bin/ipmitool mc info ----------------

Device ID                 : 189
Device Revision           : 1
Firmware Revision         : 1.14
IPMI Version              : 2.0
Manufacturer ID           : 10297
Manufacturer Name         : Advantech
Product ID                : 12368 (0x3050)
Product Name              : Unknown (0x3050)
Device Available          : yes
Provides Device SDRs      : yes
Additional Device Support :
    Sensor Device
    SEL Device
    FRU Inventory Device
    IPMB Event Generator
Aux Firmware Rev Info     : 
    0x00
    0x00
    0x00
    0x00

------------  /usr/bin/ipmitool mc watchdog get ----------------

Watchdog Timer Use:     BIOS FRB2 (0x01)
Watchdog Timer Is:      Stopped
Watchdog Timer Actions: No action (0x00)
Pre-timeout interval:   0 seconds
Timer Expiration Flags: 0x00
Initial Countdown:      0 sec
Present Countdown:      0 sec

------------  /usr/bin/ipmitool sel time get ----------------

09/29/2026 10:20:23

------------  /usr/bin/ipmitool sel ----------------

SEL Information
Version          : 1.5 (v1.5, v2 compliant)
Entries          : 95
Free Space       : 64000 bytes 
Percent Used     : 2%
Last Add Time    : 09/28/2026 05:59:32
Last Del Time    : Not Available
Overflow         : false
Supported Cmds   : 'Reserve' 'Get Alloc Info' 
# of Alloc Units : 4095
Alloc Unit Size  : 16
# Free Units     : 4000
Largest Free Blk : 4000
Max Record Size  : 1

------------  /usr/bin/ipmitool sel list ----------------

   1 | 10/13/2025 | 17:21:38 | System Boot Initiated #0x06 | System Restart | Asserted
   2 | 10/13/2025 | 17:24:18 | System ACPI Power State #0x04 | S5/G2: soft-off | Asserted
   3 | 10/13/2025 | 17:25:43 | Power Supply #0x2d | Power Supply AC lost | Asserted
   4 | 10/13/2025 | 17:25:43 | Power Supply #0x2e | Power Supply AC lost | Asserted
   5 |  Pre-Init  |0000000010| Unknown #0x0c |  | Asserted
   6 |  Pre-Init  |0000000013| System Boot Initiated #0x06 | Initiated by power up | Asserted
   7 |  Pre-Init  |0000000016| System Boot Initiated #0x06 | System Restart | Asserted
   8 |  Pre-Init  |0000000037| System Event | Timestamp Clock Sync | Asserted
   9 | 06/09/2026 | 08:44:27 | System Event | Timestamp Clock Sync | Asserted
   a | 06/09/2026 | 08:45:00 | Power Supply #0x2d | Power Supply AC lost | Asserted
   b |  Pre-Init  |0000000010| Unknown #0x0c |  | Asserted
   c |  Pre-Init  |0000000013| System Boot Initiated #0x06 | Initiated by power up | Asserted
   d |  Pre-Init  |0000000016| System Boot Initiated #0x06 | System Restart | Asserted
   e |  Pre-Init  |0000000019| System Event | Timestamp Clock Sync | Asserted
   f | 06/09/2026 | 09:11:01 | System Event | Timestamp Clock Sync | Asserted
  10 | 06/09/2026 | 09:48:43 | Power Supply #0x2d | Power Supply AC lost | Asserted
  11 |  Pre-Init  |0000000012| Unknown #0x0c |  | Asserted
  12 |  Pre-Init  |0000000015| System Boot Initiated #0x06 | Initiated by power up | Asserted
  13 |  Pre-Init  |0000000018| System Boot Initiated #0x06 | System Restart | Asserted
  14 |  Pre-Init  |0000000021| System Event | Timestamp Clock Sync | Asserted
  15 | 06/09/2026 | 11:56:56 | System Event | Timestamp Clock Sync | Asserted
  16 | 06/18/2026 | 12:30:44 | Power Supply #0x2e | Power Supply AC lost | Asserted
  17 |  Pre-Init  |0000000010| Unknown #0x0c |  | Asserted
  18 |  Pre-Init  |0000000013| System Boot Initiated #0x06 | Initiated by power up | Asserted
  19 |  Pre-Init  |0000000016| System Boot Initiated #0x06 | System Restart | Asserted
  1a |  Pre-Init  |0000000019| System Event | Timestamp Clock Sync | Asserted
  1b | 06/18/2026 | 12:31:34 | System Event | Timestamp Clock Sync | Asserted
  1c |  Pre-Init  |0000000010| Unknown #0x0c |  | Asserted
  1d |  Pre-Init  |0000000014| System Boot Initiated #0x06 | Initiated by power up | Asserted
  1e |  Pre-Init  |0000000017| System Boot Initiated #0x06 | System Restart | Asserted
  1f |  Pre-Init  |0000000020| System Event | Timestamp Clock Sync | Asserted
  20 | 08/12/2026 | 11:39:57 | System Event | Timestamp Clock Sync | Asserted
  21 |  Pre-Init  |0000000011| Unknown #0x0c |  | Asserted
  22 |  Pre-Init  |0000000014| System Boot Initiated #0x06 | Initiated by power up | Asserted
  23 |  Pre-Init  |0000000017| System Boot Initiated #0x06 | System Restart | Asserted
  24 |  Pre-Init  |0000000020| System Event | Timestamp Clock Sync | Asserted
  25 | 08/12/2026 | 13:26:10 | System Event | Timestamp Clock Sync | Asserted
  26 | 08/12/2026 | 14:33:15 | System ACPI Power State #0x04 | S5/G2: soft-off | Asserted
  27 | 08/12/2026 | 14:33:15 | Power Supply #0x2d | Power Supply AC lost | Asserted
  28 | 08/12/2026 | 14:33:15 | Power Supply #0x2e | Power Supply AC lost | Asserted
  29 |  Pre-Init  |0000000010| Unknown #0x0c |  | Asserted
  2a |  Pre-Init  |0000000013| System Boot Initiated #0x06 | Initiated by power up | Asserted
  2b |  Pre-Init  |0000000016| System Boot Initiated #0x06 | System Restart | Asserted
  2c |  Pre-Init  |0000000019| System Event | Timestamp Clock Sync | Asserted
  2d | 08/12/2026 | 14:33:48 | System Event | Timestamp Clock Sync | Asserted
  2e |  Pre-Init  |0000000010| Unknown #0x0c |  | Asserted
  2f |  Pre-Init  |0000000014| System Boot Initiated #0x06 | Initiated by power up | Asserted
  30 |  Pre-Init  |0000000017| System Boot Initiated #0x06 | System Restart | Asserted
  31 |  Pre-Init  |0000000020| System Event | Timestamp Clock Sync | Asserted
  32 | 08/17/2026 | 13:28:05 | System Event | Timestamp Clock Sync | Asserted
  33 |  Pre-Init  |0000000013| Unknown #0x0c |  | Asserted
  34 |  Pre-Init  |0000000016| System Boot Initiated #0x06 | Initiated by power up | Asserted
  35 |  Pre-Init  |0000000019| System Boot Initiated #0x06 | System Restart | Asserted
  36 |  Pre-Init  |0000000022| System Event | Timestamp Clock Sync | Asserted
  37 | 08/17/2026 | 13:33:28 | System Event | Timestamp Clock Sync | Asserted
  38 |  Pre-Init  |0000000011| Unknown #0x0c |  | Asserted
  39 |  Pre-Init  |0000000014| System Boot Initiated #0x06 | Initiated by power up | Asserted
  3a |  Pre-Init  |0000000017| System Boot Initiated #0x06 | System Restart | Asserted
  3b |  Pre-Init  |0000000021| System Event | Timestamp Clock Sync | Asserted
  3c | 08/17/2026 | 13:43:56 | System Event | Timestamp Clock Sync | Asserted
  3d |  Pre-Init  |0000000010| Unknown #0x0c |  | Asserted
  3e |  Pre-Init  |0000000013| System Boot Initiated #0x06 | Initiated by power up | Asserted
  3f |  Pre-Init  |0000000016| System Boot Initiated #0x06 | System Restart | Asserted
  40 |  Pre-Init  |0000000019| System Event | Timestamp Clock Sync | Asserted
  41 | 08/20/2026 | 09:53:03 | System Event | Timestamp Clock Sync | Asserted
  42 |  Pre-Init  |0000000011| Unknown #0x0c |  | Asserted
  43 |  Pre-Init  |0000000014| System Boot Initiated #0x06 | Initiated by power up | Asserted
  44 |  Pre-Init  |0000000017| System Boot Initiated #0x06 | System Restart | Asserted
  45 |  Pre-Init  |0000000020| System Event | Timestamp Clock Sync | Asserted
  46 | 09/04/2026 | 07:54:50 | System Event | Timestamp Clock Sync | Asserted
  47 |  Pre-Init  |0000000013| Unknown #0x0c |  | Asserted
  48 |  Pre-Init  |0000000016| System Boot Initiated #0x06 | Initiated by power up | Asserted
  49 |  Pre-Init  |0000000019| System Boot Initiated #0x06 | System Restart | Asserted
  4a |  Pre-Init  |0000000022| System Event | Timestamp Clock Sync | Asserted
  4b | 09/04/2026 | 07:57:39 | System Event | Timestamp Clock Sync | Asserted
  4c |  Pre-Init  |0000000011| Unknown #0x0c |  | Asserted
  4d |  Pre-Init  |0000000014| System Boot Initiated #0x06 | Initiated by power up | Asserted
  4e |  Pre-Init  |0000000017| System Boot Initiated #0x06 | System Restart | Asserted
  4f |  Pre-Init  |0000000037| System Event | Timestamp Clock Sync | Asserted
  50 | 09/17/2026 | 13:21:20 | System Event | Timestamp Clock Sync | Asserted
  51 |  Pre-Init  |0000000010| Unknown #0x0c |  | Asserted
  52 |  Pre-Init  |0000000013| System Boot Initiated #0x06 | Initiated by power up | Asserted
  53 |  Pre-Init  |0000000016| System Boot Initiated #0x06 | System Restart | Asserted
  54 |  Pre-Init  |0000000019| System Event | Timestamp Clock Sync | Asserted
  55 | 09/28/2026 | 05:51:58 | System Event | Timestamp Clock Sync | Asserted
  56 |  Pre-Init  |0000000014| Unknown #0x0c |  | Asserted
  57 |  Pre-Init  |0000000017| System Boot Initiated #0x06 | Initiated by power up | Asserted
  58 |  Pre-Init  |0000000020| System Boot Initiated #0x06 | System Restart | Asserted
  59 |  Pre-Init  |0000000023| System Event | Timestamp Clock Sync | Asserted
  5a | 09/28/2026 | 05:53:43 | System Event | Timestamp Clock Sync | Asserted
  5b |  Pre-Init  |0000000011| Unknown #0x0c |  | Asserted
  5c |  Pre-Init  |0000000014| System Boot Initiated #0x06 | Initiated by power up | Asserted
  5d |  Pre-Init  |0000000017| System Boot Initiated #0x06 | System Restart | Asserted
  5e |  Pre-Init  |0000000020| System Event | Timestamp Clock Sync | Asserted
  5f | 09/28/2026 | 05:59:32 | System Event | Timestamp Clock Sync | Asserted

------------  /usr/bin/ipmitool sel elist ----------------

   1 | 10/13/2025 | 17:21:38 | System Boot Initiated SYSTEM_RESET | System Restart | Asserted
   2 | 10/13/2025 | 17:24:18 | System ACPI Power State ACPI_STATE | S5/G2: soft-off | Asserted
   3 | 10/13/2025 | 17:25:43 | Power Supply PSU1 | Power Supply AC lost | Asserted
   4 | 10/13/2025 | 17:25:43 | Power Supply PSU2 | Power Supply AC lost | Asserted
   5 |  Pre-Init  |0000000010| Unknown INTEGRITY |  | Asserted
   6 |  Pre-Init  |0000000013| System Boot Initiated SYSTEM_RESET | Initiated by power up | Asserted
   7 |  Pre-Init  |0000000016| System Boot Initiated SYSTEM_RESET | System Restart | Asserted
   8 |  Pre-Init  |0000000037| System Event | Timestamp Clock Sync | Asserted
   9 | 06/09/2026 | 08:44:27 | System Event | Timestamp Clock Sync | Asserted
   a | 06/09/2026 | 08:45:00 | Power Supply PSU1 | Power Supply AC lost | Asserted
   b |  Pre-Init  |0000000010| Unknown INTEGRITY |  | Asserted
   c |  Pre-Init  |0000000013| System Boot Initiated SYSTEM_RESET | Initiated by power up | Asserted
   d |  Pre-Init  |0000000016| System Boot Initiated SYSTEM_RESET | System Restart | Asserted
   e |  Pre-Init  |0000000019| System Event | Timestamp Clock Sync | Asserted
   f | 06/09/2026 | 09:11:01 | System Event | Timestamp Clock Sync | Asserted
  10 | 06/09/2026 | 09:48:43 | Power Supply PSU1 | Power Supply AC lost | Asserted
  11 |  Pre-Init  |0000000012| Unknown INTEGRITY |  | Asserted
  12 |  Pre-Init  |0000000015| System Boot Initiated SYSTEM_RESET | Initiated by power up | Asserted
  13 |  Pre-Init  |0000000018| System Boot Initiated SYSTEM_RESET | System Restart | Asserted
  14 |  Pre-Init  |0000000021| System Event | Timestamp Clock Sync | Asserted
  15 | 06/09/2026 | 11:56:56 | System Event | Timestamp Clock Sync | Asserted
  16 | 06/18/2026 | 12:30:44 | Power Supply PSU2 | Power Supply AC lost | Asserted
  17 |  Pre-Init  |0000000010| Unknown INTEGRITY |  | Asserted
  18 |  Pre-Init  |0000000013| System Boot Initiated SYSTEM_RESET | Initiated by power up | Asserted
  19 |  Pre-Init  |0000000016| System Boot Initiated SYSTEM_RESET | System Restart | Asserted
  1a |  Pre-Init  |0000000019| System Event | Timestamp Clock Sync | Asserted
  1b | 06/18/2026 | 12:31:34 | System Event | Timestamp Clock Sync | Asserted
  1c |  Pre-Init  |0000000010| Unknown INTEGRITY |  | Asserted
  1d |  Pre-Init  |0000000014| System Boot Initiated SYSTEM_RESET | Initiated by power up | Asserted
  1e |  Pre-Init  |0000000017| System Boot Initiated SYSTEM_RESET | System Restart | Asserted
  1f |  Pre-Init  |0000000020| System Event | Timestamp Clock Sync | Asserted
  20 | 08/12/2026 | 11:39:57 | System Event | Timestamp Clock Sync | Asserted
  21 |  Pre-Init  |0000000011| Unknown INTEGRITY |  | Asserted
  22 |  Pre-Init  |0000000014| System Boot Initiated SYSTEM_RESET | Initiated by power up | Asserted
  23 |  Pre-Init  |0000000017| System Boot Initiated SYSTEM_RESET | System Restart | Asserted
  24 |  Pre-Init  |0000000020| System Event | Timestamp Clock Sync | Asserted
  25 | 08/12/2026 | 13:26:10 | System Event | Timestamp Clock Sync | Asserted
  26 | 08/12/2026 | 14:33:15 | System ACPI Power State ACPI_STATE | S5/G2: soft-off | Asserted
  27 | 08/12/2026 | 14:33:15 | Power Supply PSU1 | Power Supply AC lost | Asserted
  28 | 08/12/2026 | 14:33:15 | Power Supply PSU2 | Power Supply AC lost | Asserted
  29 |  Pre-Init  |0000000010| Unknown INTEGRITY |  | Asserted
  2a |  Pre-Init  |0000000013| System Boot Initiated SYSTEM_RESET | Initiated by power up | Asserted
  2b |  Pre-Init  |0000000016| System Boot Initiated SYSTEM_RESET | System Restart | Asserted
  2c |  Pre-Init  |0000000019| System Event | Timestamp Clock Sync | Asserted
  2d | 08/12/2026 | 14:33:48 | System Event | Timestamp Clock Sync | Asserted
  2e |  Pre-Init  |0000000010| Unknown INTEGRITY |  | Asserted
  2f |  Pre-Init  |0000000014| System Boot Initiated SYSTEM_RESET | Initiated by power up | Asserted
  30 |  Pre-Init  |0000000017| System Boot Initiated SYSTEM_RESET | System Restart | Asserted
  31 |  Pre-Init  |0000000020| System Event | Timestamp Clock Sync | Asserted
  32 | 08/17/2026 | 13:28:05 | System Event | Timestamp Clock Sync | Asserted
  33 |  Pre-Init  |0000000013| Unknown INTEGRITY |  | Asserted
  34 |  Pre-Init  |0000000016| System Boot Initiated SYSTEM_RESET | Initiated by power up | Asserted
  35 |  Pre-Init  |0000000019| System Boot Initiated SYSTEM_RESET | System Restart | Asserted
  36 |  Pre-Init  |0000000022| System Event | Timestamp Clock Sync | Asserted
  37 | 08/17/2026 | 13:33:28 | System Event | Timestamp Clock Sync | Asserted
  38 |  Pre-Init  |0000000011| Unknown INTEGRITY |  | Asserted
  39 |  Pre-Init  |0000000014| System Boot Initiated SYSTEM_RESET | Initiated by power up | Asserted
  3a |  Pre-Init  |0000000017| System Boot Initiated SYSTEM_RESET | System Restart | Asserted
  3b |  Pre-Init  |0000000021| System Event | Timestamp Clock Sync | Asserted
  3c | 08/17/2026 | 13:43:56 | System Event | Timestamp Clock Sync | Asserted
  3d |  Pre-Init  |0000000010| Unknown INTEGRITY |  | Asserted
  3e |  Pre-Init  |0000000013| System Boot Initiated SYSTEM_RESET | Initiated by power up | Asserted
  3f |  Pre-Init  |0000000016| System Boot Initiated SYSTEM_RESET | System Restart | Asserted
  40 |  Pre-Init  |0000000019| System Event | Timestamp Clock Sync | Asserted
  41 | 08/20/2026 | 09:53:03 | System Event | Timestamp Clock Sync | Asserted
  42 |  Pre-Init  |0000000011| Unknown INTEGRITY |  | Asserted
  43 |  Pre-Init  |0000000014| System Boot Initiated SYSTEM_RESET | Initiated by power up | Asserted
  44 |  Pre-Init  |0000000017| System Boot Initiated SYSTEM_RESET | System Restart | Asserted
  45 |  Pre-Init  |0000000020| System Event | Timestamp Clock Sync | Asserted
  46 | 09/04/2026 | 07:54:50 | System Event | Timestamp Clock Sync | Asserted
  47 |  Pre-Init  |0000000013| Unknown INTEGRITY |  | Asserted
  48 |  Pre-Init  |0000000016| System Boot Initiated SYSTEM_RESET | Initiated by power up | Asserted
  49 |  Pre-Init  |0000000019| System Boot Initiated SYSTEM_RESET | System Restart | Asserted
  4a |  Pre-Init  |0000000022| System Event | Timestamp Clock Sync | Asserted
  4b | 09/04/2026 | 07:57:39 | System Event | Timestamp Clock Sync | Asserted
  4c |  Pre-Init  |0000000011| Unknown INTEGRITY |  | Asserted
  4d |  Pre-Init  |0000000014| System Boot Initiated SYSTEM_RESET | Initiated by power up | Asserted
  4e |  Pre-Init  |0000000017| System Boot Initiated SYSTEM_RESET | System Restart | Asserted
  4f |  Pre-Init  |0000000037| System Event | Timestamp Clock Sync | Asserted
  50 | 09/17/2026 | 13:21:20 | System Event | Timestamp Clock Sync | Asserted
  51 |  Pre-Init  |0000000010| Unknown INTEGRITY |  | Asserted
  52 |  Pre-Init  |0000000013| System Boot Initiated SYSTEM_RESET | Initiated by power up | Asserted
  53 |  Pre-Init  |0000000016| System Boot Initiated SYSTEM_RESET | System Restart | Asserted
  54 |  Pre-Init  |0000000019| System Event | Timestamp Clock Sync | Asserted
  55 | 09/28/2026 | 05:51:58 | System Event | Timestamp Clock Sync | Asserted
  56 |  Pre-Init  |0000000014| Unknown INTEGRITY |  | Asserted
  57 |  Pre-Init  |0000000017| System Boot Initiated SYSTEM_RESET | Initiated by power up | Asserted
  58 |  Pre-Init  |0000000020| System Boot Initiated SYSTEM_RESET | System Restart | Asserted
  59 |  Pre-Init  |0000000023| System Event | Timestamp Clock Sync | Asserted
  5a | 09/28/2026 | 05:53:43 | System Event | Timestamp Clock Sync | Asserted
  5b |  Pre-Init  |0000000011| Unknown INTEGRITY |  | Asserted
  5c |  Pre-Init  |0000000014| System Boot Initiated SYSTEM_RESET | Initiated by power up | Asserted
  5d |  Pre-Init  |0000000017| System Boot Initiated SYSTEM_RESET | System Restart | Asserted
  5e |  Pre-Init  |0000000020| System Event | Timestamp Clock Sync | Asserted
  5f | 09/28/2026 | 05:59:32 | System Event | Timestamp Clock Sync | Asserted

------------  /usr/bin/ipmitool sel elist -v ----------------

Running Get PICMG Properties my_addr 0x20, transit 0, target 0
Error response 0xc1 from Get PICMG Properities
Running Get VSO Capabilities my_addr 0x20, transit 0, target 0
Invalid completion code received: Invalid command
Discovered IPMB address 0x0
SEL Record ID          : 0001
 Record Type           : 02
 Timestamp             : 10/13/2025 17:21:38
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c700ff
 Description           : System Restart

SEL Record ID          : 0002
 Record Type           : 02
 Timestamp             : 10/13/2025 17:24:18
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System ACPI Power State
 Sensor Number         : 04
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 05ffff
 Description           : S5/G2: soft-off

SEL Record ID          : 0003
 Record Type           : 02
 Timestamp             : 10/13/2025 17:25:43
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Power Supply
 Sensor Number         : 2d
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 03ffff
 Description           : Power Supply AC lost

SEL Record ID          : 0004
 Record Type           : 02
 Timestamp             : 10/13/2025 17:25:43
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Power Supply
 Sensor Number         : 2e
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 03ffff
 Description           : Power Supply AC lost

SEL Record ID          : 0005
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:10
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Unknown
 Sensor Number         : 0c
 Event Type            : OEM
 Event Direction       : Assertion Event
 Event Data            : a00190
 Description           : 

SEL Record ID          : 0006
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:13
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 00ffff
 Description           : Initiated by power up

SEL Record ID          : 0007
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:16
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c700ff
 Description           : System Restart

SEL Record ID          : 0008
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:37
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c500ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0009
 Record Type           : 02
 Timestamp             : 06/09/2026 08:44:27
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c580ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 000a
 Record Type           : 02
 Timestamp             : 06/09/2026 08:45:00
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Power Supply
 Sensor Number         : 2d
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 03ffff
 Description           : Power Supply AC lost

SEL Record ID          : 000b
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:10
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Unknown
 Sensor Number         : 0c
 Event Type            : OEM
 Event Direction       : Assertion Event
 Event Data            : a00190
 Description           : 

SEL Record ID          : 000c
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:13
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 00ffff
 Description           : Initiated by power up

SEL Record ID          : 000d
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:16
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c700ff
 Description           : System Restart

SEL Record ID          : 000e
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:19
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c500ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 000f
 Record Type           : 02
 Timestamp             : 06/09/2026 09:11:01
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c580ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0010
 Record Type           : 02
 Timestamp             : 06/09/2026 09:48:43
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Power Supply
 Sensor Number         : 2d
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 03ffff
 Description           : Power Supply AC lost

SEL Record ID          : 0011
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:12
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Unknown
 Sensor Number         : 0c
 Event Type            : OEM
 Event Direction       : Assertion Event
 Event Data            : a00190
 Description           : 

SEL Record ID          : 0012
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:15
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 00ffff
 Description           : Initiated by power up

SEL Record ID          : 0013
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:18
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c700ff
 Description           : System Restart

SEL Record ID          : 0014
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:21
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c500ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0015
 Record Type           : 02
 Timestamp             : 06/09/2026 11:56:56
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c580ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0016
 Record Type           : 02
 Timestamp             : 06/18/2026 12:30:44
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Power Supply
 Sensor Number         : 2e
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 03ffff
 Description           : Power Supply AC lost

SEL Record ID          : 0017
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:10
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Unknown
 Sensor Number         : 0c
 Event Type            : OEM
 Event Direction       : Assertion Event
 Event Data            : a00190
 Description           : 

SEL Record ID          : 0018
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:13
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 00ffff
 Description           : Initiated by power up

SEL Record ID          : 0019
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:16
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c700ff
 Description           : System Restart

SEL Record ID          : 001a
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:19
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c500ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 001b
 Record Type           : 02
 Timestamp             : 06/18/2026 12:31:34
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c580ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 001c
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:10
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Unknown
 Sensor Number         : 0c
 Event Type            : OEM
 Event Direction       : Assertion Event
 Event Data            : a00190
 Description           : 

SEL Record ID          : 001d
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:14
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 00ffff
 Description           : Initiated by power up

SEL Record ID          : 001e
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:17
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c700ff
 Description           : System Restart

SEL Record ID          : 001f
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:20
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c500ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0020
 Record Type           : 02
 Timestamp             : 08/12/2026 11:39:57
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c580ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0021
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:11
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Unknown
 Sensor Number         : 0c
 Event Type            : OEM
 Event Direction       : Assertion Event
 Event Data            : a00190
 Description           : 

SEL Record ID          : 0022
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:14
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 00ffff
 Description           : Initiated by power up

SEL Record ID          : 0023
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:17
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c700ff
 Description           : System Restart

SEL Record ID          : 0024
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:20
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c500ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0025
 Record Type           : 02
 Timestamp             : 08/12/2026 13:26:10
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c580ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0026
 Record Type           : 02
 Timestamp             : 08/12/2026 14:33:15
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System ACPI Power State
 Sensor Number         : 04
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 05ffff
 Description           : S5/G2: soft-off

SEL Record ID          : 0027
 Record Type           : 02
 Timestamp             : 08/12/2026 14:33:15
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Power Supply
 Sensor Number         : 2d
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 03ffff
 Description           : Power Supply AC lost

SEL Record ID          : 0028
 Record Type           : 02
 Timestamp             : 08/12/2026 14:33:15
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Power Supply
 Sensor Number         : 2e
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 03ffff
 Description           : Power Supply AC lost

SEL Record ID          : 0029
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:10
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Unknown
 Sensor Number         : 0c
 Event Type            : OEM
 Event Direction       : Assertion Event
 Event Data            : a00190
 Description           : 

SEL Record ID          : 002a
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:13
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 00ffff
 Description           : Initiated by power up

SEL Record ID          : 002b
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:16
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c700ff
 Description           : System Restart

SEL Record ID          : 002c
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:19
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c500ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 002d
 Record Type           : 02
 Timestamp             : 08/12/2026 14:33:48
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c580ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 002e
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:10
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Unknown
 Sensor Number         : 0c
 Event Type            : OEM
 Event Direction       : Assertion Event
 Event Data            : a00190
 Description           : 

SEL Record ID          : 002f
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:14
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 00ffff
 Description           : Initiated by power up

SEL Record ID          : 0030
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:17
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c700ff
 Description           : System Restart

SEL Record ID          : 0031
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:20
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c500ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0032
 Record Type           : 02
 Timestamp             : 08/17/2026 13:28:05
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c580ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0033
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:13
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Unknown
 Sensor Number         : 0c
 Event Type            : OEM
 Event Direction       : Assertion Event
 Event Data            : a00190
 Description           : 

SEL Record ID          : 0034
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:16
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 00ffff
 Description           : Initiated by power up

SEL Record ID          : 0035
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:19
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c700ff
 Description           : System Restart

SEL Record ID          : 0036
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:22
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c500ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0037
 Record Type           : 02
 Timestamp             : 08/17/2026 13:33:28
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c580ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0038
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:11
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Unknown
 Sensor Number         : 0c
 Event Type            : OEM
 Event Direction       : Assertion Event
 Event Data            : a00190
 Description           : 

SEL Record ID          : 0039
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:14
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 00ffff
 Description           : Initiated by power up

SEL Record ID          : 003a
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:17
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c700ff
 Description           : System Restart

SEL Record ID          : 003b
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:21
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c500ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 003c
 Record Type           : 02
 Timestamp             : 08/17/2026 13:43:56
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c580ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 003d
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:10
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Unknown
 Sensor Number         : 0c
 Event Type            : OEM
 Event Direction       : Assertion Event
 Event Data            : a00190
 Description           : 

SEL Record ID          : 003e
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:13
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 00ffff
 Description           : Initiated by power up

SEL Record ID          : 003f
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:16
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c700ff
 Description           : System Restart

SEL Record ID          : 0040
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:19
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c500ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0041
 Record Type           : 02
 Timestamp             : 08/20/2026 09:53:03
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c580ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0042
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:11
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Unknown
 Sensor Number         : 0c
 Event Type            : OEM
 Event Direction       : Assertion Event
 Event Data            : a00190
 Description           : 

SEL Record ID          : 0043
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:14
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 00ffff
 Description           : Initiated by power up

SEL Record ID          : 0044
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:17
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c700ff
 Description           : System Restart

SEL Record ID          : 0045
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:20
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c500ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0046
 Record Type           : 02
 Timestamp             : 09/04/2026 07:54:50
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c580ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0047
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:13
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Unknown
 Sensor Number         : 0c
 Event Type            : OEM
 Event Direction       : Assertion Event
 Event Data            : a00190
 Description           : 

SEL Record ID          : 0048
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:16
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 00ffff
 Description           : Initiated by power up

SEL Record ID          : 0049
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:19
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c700ff
 Description           : System Restart

SEL Record ID          : 004a
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:22
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c500ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 004b
 Record Type           : 02
 Timestamp             : 09/04/2026 07:57:39
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c580ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 004c
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:11
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Unknown
 Sensor Number         : 0c
 Event Type            : OEM
 Event Direction       : Assertion Event
 Event Data            : a00190
 Description           : 

SEL Record ID          : 004d
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:14
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 00ffff
 Description           : Initiated by power up

SEL Record ID          : 004e
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:17
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c700ff
 Description           : System Restart

SEL Record ID          : 004f
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:37
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c500ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0050
 Record Type           : 02
 Timestamp             : 09/17/2026 13:21:20
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c580ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0051
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:10
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Unknown
 Sensor Number         : 0c
 Event Type            : OEM
 Event Direction       : Assertion Event
 Event Data            : a00190
 Description           : 

SEL Record ID          : 0052
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:13
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 00ffff
 Description           : Initiated by power up

SEL Record ID          : 0053
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:16
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c700ff
 Description           : System Restart

SEL Record ID          : 0054
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:19
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c500ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0055
 Record Type           : 02
 Timestamp             : 09/28/2026 05:51:58
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c580ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 0056
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:14
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Unknown
 Sensor Number         : 0c
 Event Type            : OEM
 Event Direction       : Assertion Event
 Event Data            : a00190
 Description           : 

SEL Record ID          : 0057
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:17
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 00ffff
 Description           : Initiated by power up

SEL Record ID          : 0058
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:20
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c700ff
 Description           : System Restart

SEL Record ID          : 0059
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:23
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c500ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 005a
 Record Type           : 02
 Timestamp             : 09/28/2026 05:53:43
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c580ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 005b
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:11
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : Unknown
 Sensor Number         : 0c
 Event Type            : OEM
 Event Direction       : Assertion Event
 Event Data            : a00190
 Description           : 

SEL Record ID          : 005c
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:14
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : 00ffff
 Description           : Initiated by power up

SEL Record ID          : 005d
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:17
 Generator ID          : 0020
 EvM Revision          : 04
 Sensor Type           : System Boot Initiated
 Sensor Number         : 06
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c700ff
 Description           : System Restart

SEL Record ID          : 005e
 Record Type           : 02
 Timestamp             : 01/01/1970 00:00:20
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c500ff
 Description           : Timestamp Clock Sync

SEL Record ID          : 005f
 Record Type           : 02
 Timestamp             : 09/28/2026 05:59:32
 Generator ID          : 0001
 EvM Revision          : 04
 Sensor Type           : System Event
 Sensor Number         : 00
 Event Type            : Sensor-specific Discrete
 Event Direction       : Assertion Event
 Event Data            : c580ff
 Description           : Timestamp Clock Sync


------------  /usr/bin/ipmitool sdr -v ----------------

Running Get PICMG Properties my_addr 0x20, transit 0, target 0
Error response 0xc1 from Get PICMG Properities
Running Get VSO Capabilities my_addr 0x20, transit 0, target 0
Invalid completion code received: Invalid command
Discovered IPMB address 0x0
Sensor ID              : BMC_HEALTH (0x1)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Discrete): Management Subsys Health (0x28)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 Assertions Enabled    : Management Subsys Health
                         [Sensor failure]
 Deassertions Enabled  : Management Subsys Health
                         [Sensor failure]
 OEM                   : 0

Sensor ID              : VERSION_CHANGE (0x2)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Discrete): Version Change (0x2b)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 Assertions Enabled    : Version Change
 Deassertions Enabled  : Version Change
 OEM                   : 0

Sensor ID              : BMC_WATCHDOG (0x3)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Discrete): Watchdog2 (0x23)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 Assertions Enabled    : Watchdog2
                         [Timer expired]
                         [Hard reset]
                         [Power down]
                         [Power cycle]
 Deassertions Enabled  : Watchdog2
                         [Timer expired]
                         [Hard reset]
                         [Power down]
                         [Power cycle]
 OEM                   : 0

Sensor ID              : ACPI_STATE (0x4)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Discrete): System ACPI Power State (0x22)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 States Asserted       : System ACPI Power State
                         [S0/G0: working]
 Assertions Enabled    : System ACPI Power State
                         [S0/G0: working]
                         [S3: sleeping, processor & hw context lost, memory retained]
                         [S4: non-volatile sleep/suspend-to-disk]
                         [S5/G2: soft-off]
                         [G3: mechanical off]
 Deassertions Enabled  : System ACPI Power State
                         [S0/G0: working]
                         [S3: sleeping, processor & hw context lost, memory retained]
                         [S4: non-volatile sleep/suspend-to-disk]
                         [S5/G2: soft-off]
                         [G3: mechanical off]
 OEM                   : 0

Sensor ID              : PROC_STATE (0x5)
 Entity ID             : 3.0 (Processor)
 Sensor Type (Discrete): Processor (0x07)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 Assertions Enabled    : Processor
                         [IERR]
                         [Thermal Trip]
                         [FRB2/Hang in POST failure]
                         [Throttled]
                         [Uncorrectable machine check exception]
                         [Correctable machine check error]
 Deassertions Enabled  : Processor
                         [IERR]
                         [Thermal Trip]
                         [FRB2/Hang in POST failure]
                         [Throttled]
                         [Uncorrectable machine check exception]
                         [Correctable machine check error]
 OEM                   : 0

Sensor ID              : SYSTEM_RESET (0x6)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Discrete): System Boot Initiated (0x1d)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 States Asserted       : System Boot Initiated
                         [System Restart]
 Assertions Enabled    : System Boot Initiated
                         [Initiated by power up]
                         [Initiated by hard reset]
                         [System Restart]
 Deassertions Enabled  : System Boot Initiated
                         [Initiated by power up]
                         [Initiated by hard reset]
                         [System Restart]
 OEM                   : 0

Sensor ID              : FW_PROGRESS (0x7)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Discrete): System Firmwares (0x0f)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 Assertions Enabled    : System Firmwares
                         [Unknown Error]
                         [Unknown Hang]
                         [Unknown Progress]
 Deassertions Enabled  : System Firmwares
                         [Unknown Error]
                         [Unknown Hang]
                         [Unknown Progress]
 OEM                   : 0

Sensor ID              : PCIE_CR_INT (0x8)
 Entity ID             : 49.0 (PCI Express Bus)
 Sensor Type (Discrete): Critical Interrupt (0x13)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 Assertions Enabled    : Critical Interrupt
                         [NMI/Diag Interrupt]
                         [I/O Channel check NMI]
                         [PCI PERR]
 Deassertions Enabled  : Critical Interrupt
                         [NMI/Diag Interrupt]
                         [I/O Channel check NMI]
                         [PCI PERR]
 OEM                   : 0

Sensor ID              : INTEGRITY (0xc)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Discrete): Unknown (0xc0)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 OEM                   : C0

Sensor ID              : BIOS_POST (0xd)
 Entity ID             : 34.0 (BIOS)
 Sensor Type (Discrete): System Firmwares (0x0f)
 Sensor Reading        : 0h
 Event Message Control : No Events From Sensor
 Event Status          : Event Messages Disabled
 Event Enable          : Event Messages Disabled
 OEM                   : 0

Sensor ID              : BOARD-POWER (0xe)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Threshold)  : Other (0x0b)
 Sensor Reading        : 70 (+/- 0) Watts
 Status                : ok
 Positive Hysteresis   : Unspecified
 Negative Hysteresis   : Unspecified
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : 
 Settable Thresholds   : 
 Assertion Events      : 
 Assertions Enabled    : 

Sensor ID              : PAY_12-VOL (0xf)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 12 (+/- 0) Volts
 Status                : ok
 Upper critical        : 13.248
 Lower critical        : 10.752
 Positive Hysteresis   : 0.288
 Negative Hysteresis   : 0.288
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PAY_5_0-VOL (0x10)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 5.072 (+/- 0) Volts
 Status                : ok
 Upper critical        : 5.361
 Lower critical        : 4.655
 Positive Hysteresis   : 0.096
 Negative Hysteresis   : 0.096
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PAY_5_0_SB-VOL (0x11)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 5.040 (+/- 0) Volts
 Status                : ok
 Upper critical        : 5.361
 Lower critical        : 4.655
 Positive Hysteresis   : 0.096
 Negative Hysteresis   : 0.096
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PAY_3_3-VOL (0x12)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 3.302 (+/- 0) Volts
 Status                : ok
 Upper critical        : 3.519
 Lower critical        : 3.061
 Positive Hysteresis   : 0.072
 Negative Hysteresis   : 0.072
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PAY_3_3_SB-VOL (0x13)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 3.302 (+/- 0) Volts
 Status                : ok
 Upper critical        : 3.519
 Lower critical        : 3.061
 Positive Hysteresis   : 0.072
 Negative Hysteresis   : 0.072
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : BAT_3_0-VOL (0x14)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 3.109 (+/- 0) Volts
 Status                : ok
 Upper critical        : 3.254
 Lower critical        : 1.928
 Positive Hysteresis   : 0.072
 Negative Hysteresis   : 0.072
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PCH_1_8_SB-VOL (0x15)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 1.808 (+/- 0) Volts
 Status                : ok
 Upper critical        : 1.880
 Lower critical        : 1.712
 Positive Hysteresis   : 0.032
 Negative Hysteresis   : 0.032
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : CPU_VCCIN-VOL (0x16)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 1.784 (+/- 0) Volts
 Status                : ok
 Upper critical        : 2.040
 Lower critical        : 1.448
 Positive Hysteresis   : 0.032
 Negative Hysteresis   : 0.032
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PVDDQ_ABC-VOL (0x17)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 1.224 (+/- 0) Volts
 Status                : ok
 Upper critical        : 1.304
 Lower critical        : 1.112
 Positive Hysteresis   : 0.024
 Negative Hysteresis   : 0.024
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PVDDQ_DEF-VOL (0x18)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 1.216 (+/- 0) Volts
 Status                : ok
 Upper critical        : 1.304
 Lower critical        : 1.112
 Positive Hysteresis   : 0.024
 Negative Hysteresis   : 0.024
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : BMC_1_15_SB-VOL (0x19)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 1.157 (+/- 0) Volts
 Status                : ok
 Upper critical        : 1.257
 Lower critical        : 1.044
 Positive Hysteresis   : 0.014
 Negative Hysteresis   : 0.014
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PCH_1_05_SB-VOL (0x1a)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 1.064 (+/- 0) Volts
 Status                : ok
 Upper critical        : 1.136
 Lower critical        : 0.960
 Positive Hysteresis   : 0.016
 Negative Hysteresis   : 0.016
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : CPU_VCCIO-VOL (0x1b)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 1.016 (+/- 0) Volts
 Status                : ok
 Upper critical        : 1.096
 Lower critical        : 0.904
 Positive Hysteresis   : 0.016
 Negative Hysteresis   : 0.016
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PCH_VNN_SB-VOL (0x1c)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 1.008 (+/- 0) Volts
 Status                : ok
 Upper critical        : 1.096
 Lower critical        : 0.904
 Positive Hysteresis   : 0.016
 Negative Hysteresis   : 0.016
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : CPU_VCCSA-VOL (0x1d)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 0.896 (+/- 0) Volts
 Status                : ok
 Upper critical        : 1.152
 Lower critical        : 0.456
 Positive Hysteresis   : 0.024
 Negative Hysteresis   : 0.024
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : INLET-TMP (0x1e)
 Entity ID             : 55.0 (Air Inlet)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 32 (+/- 0) degrees C
 Status                : ok
 Upper non-recoverable : 100.000
 Upper critical        : 75.000
 Upper non-critical    : 60.000
 Positive Hysteresis   : 3.000
 Negative Hysteresis   : 3.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr unr 
 Settable Thresholds   : unc ucr unr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ unr+ 
 Deassertions Enabled  : unc+ ucr+ unr+ 

Sensor ID              : OUTLET-TMP (0x1f)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 49 (+/- 0) degrees C
 Status                : ok
 Upper critical        : 75.000
 Upper non-critical    : 65.000
 Positive Hysteresis   : 3.000
 Negative Hysteresis   : 3.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr 
 Settable Thresholds   : unc ucr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ 
 Deassertions Enabled  : unc+ ucr+ 

Sensor ID              : CPU-TMP (0x20)
 Entity ID             : 3.0 (Processor)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 62 (+/- 0) degrees C
 Status                : ok
 Upper critical        : 105.000
 Upper non-critical    : 90.000
 Positive Hysteresis   : 3.000
 Negative Hysteresis   : 3.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr 
 Settable Thresholds   : unc ucr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ 
 Deassertions Enabled  : unc+ ucr+ 

Sensor ID              : HWM-TMP (0x21)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 36 (+/- 0) degrees C
 Status                : ok
 Upper non-recoverable : 80.000
 Upper critical        : 70.000
 Upper non-critical    : 60.000
 Positive Hysteresis   : 3.000
 Negative Hysteresis   : 3.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr unr 
 Settable Thresholds   : unc ucr unr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ unr+ 
 Deassertions Enabled  : unc+ ucr+ unr+ 

Sensor ID              : PCH-TMP (0x22)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 65 (+/- 0) degrees C
 Status                : ok
 Upper critical        : 100.000
 Upper non-critical    : 90.000
 Positive Hysteresis   : 3.000
 Negative Hysteresis   : 3.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr 
 Settable Thresholds   : unc ucr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ 
 Deassertions Enabled  : unc+ ucr+ 

Sensor ID              : CPU-DIMMA_1-TMP (0x23)
 Entity ID             : 32.0 (Memory Device)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 37 (+/- 0) degrees C
 Status                : ok
 Upper critical        : 95.000
 Upper non-critical    : 85.000
 Positive Hysteresis   : 3.000
 Negative Hysteresis   : 3.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr 
 Settable Thresholds   : unc ucr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ 
 Deassertions Enabled  : unc+ ucr+ 

Sensor ID              : CPU-DIMMB_1-TMP (0x24)
 Entity ID             : 32.0 (Memory Device)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 35 (+/- 0) degrees C
 Status                : ok
 Upper critical        : 95.000
 Upper non-critical    : 85.000
 Positive Hysteresis   : 3.000
 Negative Hysteresis   : 3.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr 
 Settable Thresholds   : unc ucr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ 
 Deassertions Enabled  : unc+ ucr+ 

Sensor ID              : CPU-DIMMD_1-TMP (0x25)
 Entity ID             : 32.0 (Memory Device)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 37 (+/- 0) degrees C
 Status                : ok
 Upper critical        : 95.000
 Upper non-critical    : 85.000
 Positive Hysteresis   : 3.000
 Negative Hysteresis   : 3.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr 
 Settable Thresholds   : unc ucr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ 
 Deassertions Enabled  : unc+ ucr+ 

Sensor ID              : CPU-DIMME_1-TMP (0x26)
 Entity ID             : 32.0 (Memory Device)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 36 (+/- 0) degrees C
 Status                : ok
 Upper critical        : 95.000
 Upper non-critical    : 85.000
 Positive Hysteresis   : 3.000
 Negative Hysteresis   : 3.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr 
 Settable Thresholds   : unc ucr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ 
 Deassertions Enabled  : unc+ ucr+ 

Sensor ID              : FAN1-SPEED (0x27)
 Entity ID             : 29.0 (Fan Device)
 Sensor Type (Threshold)  : Fan (0x04)
 Sensor Reading        : 5900 (+/- 0) RPM
 Status                : ok
 Lower critical        : 1200.000
 Positive Hysteresis   : 100.000
 Negative Hysteresis   : 100.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr 
 Settable Thresholds   : lcr 
 Assertion Events      : 
 Assertions Enabled    : lcr- 
 Deassertions Enabled  : lcr- 

Sensor ID              : FAN2-SPEED (0x28)
 Entity ID             : 29.0 (Fan Device)
 Sensor Type (Threshold)  : Fan (0x04)
 Sensor Reading        : 6000 (+/- 0) RPM
 Status                : ok
 Lower critical        : 1200.000
 Positive Hysteresis   : 100.000
 Negative Hysteresis   : 100.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr 
 Settable Thresholds   : lcr 
 Assertion Events      : 
 Assertions Enabled    : lcr- 
 Deassertions Enabled  : lcr- 

Sensor ID              : FAN3-SPEED (0x29)
 Entity ID             : 29.0 (Fan Device)
 Sensor Type (Threshold)  : Fan (0x04)
 Sensor Reading        : 5900 (+/- 0) RPM
 Status                : ok
 Lower critical        : 1200.000
 Positive Hysteresis   : 100.000
 Negative Hysteresis   : 100.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr 
 Settable Thresholds   : lcr 
 Assertion Events      : 
 Assertions Enabled    : lcr- 
 Deassertions Enabled  : lcr- 

Sensor ID              : PSU1 (0x2d)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Discrete): Power Supply (0x08)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 States Asserted       : Power Supply
                         [Presence detected]
 Assertions Enabled    : Power Supply
                         [Presence detected]
                         [Failure detected]
                         [Predictive failure]
                         [Power Supply AC lost]
 Deassertions Enabled  : Power Supply
                         [Presence detected]
                         [Failure detected]
                         [Predictive failure]
                         [Power Supply AC lost]
 OEM                   : 0

Sensor ID              : PSU2 (0x2e)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Discrete): Power Supply (0x08)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 States Asserted       : Power Supply
                         [Presence detected]
 Assertions Enabled    : Power Supply
                         [Presence detected]
                         [Failure detected]
                         [Predictive failure]
                         [Power Supply AC lost]
 Deassertions Enabled  : Power Supply
                         [Presence detected]
                         [Failure detected]
                         [Predictive failure]
                         [Power Supply AC lost]
 OEM                   : 0

Sensor ID              : PSU1_INTAKE-TMP (0x30)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 42 (+/- 0) degrees C
 Status                : ok
 Upper non-recoverable : 85.000
 Upper critical        : 75.000
 Upper non-critical    : 65.000
 Positive Hysteresis   : Unspecified
 Negative Hysteresis   : Unspecified
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr unr 
 Settable Thresholds   : unc ucr unr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ unr+ 
 Deassertions Enabled  : unc+ ucr+ unr+ 

Sensor ID              : PSU1_HOTSPOT-TMP (0x31)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 44 (+/- 0) degrees C
 Status                : ok
 Upper non-recoverable : 110.000
 Upper critical        : 100.000
 Upper non-critical    : 90.000
 Positive Hysteresis   : Unspecified
 Negative Hysteresis   : Unspecified
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr unr 
 Settable Thresholds   : unc ucr unr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ unr+ 
 Deassertions Enabled  : unc+ ucr+ unr+ 

Sensor ID              : PSU1_IN-VOL (0x32)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 240 (+/- 0) Volts
 Status                : ok
 Upper critical        : 264.000
 Lower critical        : 90.000
 Positive Hysteresis   : 2.000
 Negative Hysteresis   : 2.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PSU1_OUT-VOL (0x33)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 12.100 (+/- 0) Volts
 Status                : ok
 Upper critical        : 12.800
 Lower critical        : 11.500
 Positive Hysteresis   : 0.100
 Negative Hysteresis   : 0.100
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PSU1_IN-CUR (0x34)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Threshold)  : Current (0x03)
 Sensor Reading        : 0.250 (+/- 0) Amps
 Status                : ok
 Upper critical        : 18.000
 Positive Hysteresis   : 0.250
 Negative Hysteresis   : 0.250
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : ucr 
 Settable Thresholds   : ucr 
 Assertion Events      : 
 Assertions Enabled    : ucr+ 
 Deassertions Enabled  : ucr+ 

Sensor ID              : PSU1_OUT-CUR (0x35)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Threshold)  : Current (0x03)
 Sensor Reading        : 3 (+/- 0) Amps
 Status                : ok
 Upper critical        : 166.000
 Positive Hysteresis   : 1.000
 Negative Hysteresis   : 1.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : ucr 
 Settable Thresholds   : ucr 
 Assertion Events      : 
 Assertions Enabled    : ucr+ 
 Deassertions Enabled  : ucr+ 

Sensor ID              : PSU1_IN-POWER (0x36)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Threshold)  : Other (0x0b)
 Sensor Reading        : 60 (+/- 0) Watts
 Status                : ok
 Upper critical        : 2000.000
 Positive Hysteresis   : 10.000
 Negative Hysteresis   : 10.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : ucr 
 Settable Thresholds   : ucr 
 Assertion Events      : 
 Assertions Enabled    : ucr+ 
 Deassertions Enabled  : ucr+ 

Sensor ID              : PSU1_OUT-POWER (0x37)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Threshold)  : Other (0x0b)
 Sensor Reading        : 40 (+/- 0) Watts
 Status                : ok
 Upper critical        : 2000.000
 Positive Hysteresis   : 10.000
 Negative Hysteresis   : 10.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : ucr 
 Settable Thresholds   : ucr 
 Assertion Events      : 
 Assertions Enabled    : ucr+ 
 Deassertions Enabled  : ucr+ 

Sensor ID              : PSU1_FAN-SPEED (0x38)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Threshold)  : Fan (0x04)
 Sensor Reading        : 1950 (+/- 0) RPM
 Status                : ok
 Lower critical        : 450.000
 Positive Hysteresis   : 150.000
 Negative Hysteresis   : 150.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr 
 Settable Thresholds   : lcr 
 Assertion Events      : 
 Assertions Enabled    : lcr- 
 Deassertions Enabled  : lcr- 

Sensor ID              : PSU2_INTAKE-TMP (0x3a)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 37 (+/- 0) degrees C
 Status                : ok
 Upper non-recoverable : 85.000
 Upper critical        : 75.000
 Upper non-critical    : 65.000
 Positive Hysteresis   : Unspecified
 Negative Hysteresis   : Unspecified
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr unr 
 Settable Thresholds   : unc ucr unr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ unr+ 
 Deassertions Enabled  : unc+ ucr+ unr+ 

Sensor ID              : PSU2_HOTSPOT-TMP (0x3b)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 36 (+/- 0) degrees C
 Status                : ok
 Upper non-recoverable : 110.000
 Upper critical        : 100.000
 Upper non-critical    : 90.000
 Positive Hysteresis   : Unspecified
 Negative Hysteresis   : Unspecified
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr unr 
 Settable Thresholds   : unc ucr unr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ unr+ 
 Deassertions Enabled  : unc+ ucr+ unr+ 

Sensor ID              : PSU2_IN-VOL (0x3c)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 238 (+/- 0) Volts
 Status                : ok
 Upper critical        : 264.000
 Lower critical        : 90.000
 Positive Hysteresis   : 2.000
 Negative Hysteresis   : 2.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PSU2_OUT-VOL (0x3d)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 12.100 (+/- 0) Volts
 Status                : ok
 Upper critical        : 12.800
 Lower critical        : 11.500
 Positive Hysteresis   : 0.100
 Negative Hysteresis   : 0.100
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PSU2_IN-CUR (0x3e)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Threshold)  : Current (0x03)
 Sensor Reading        : 0.250 (+/- 0) Amps
 Status                : ok
 Upper critical        : 18.000
 Positive Hysteresis   : 0.250
 Negative Hysteresis   : 0.250
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : ucr 
 Settable Thresholds   : ucr 
 Assertion Events      : 
 Assertions Enabled    : ucr+ 
 Deassertions Enabled  : ucr+ 

Sensor ID              : PSU2_OUT-CUR (0x3f)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Threshold)  : Current (0x03)
 Sensor Reading        : 4 (+/- 0) Amps
 Status                : ok
 Upper critical        : 166.000
 Positive Hysteresis   : 1.000
 Negative Hysteresis   : 1.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : ucr 
 Settable Thresholds   : ucr 
 Assertion Events      : 
 Assertions Enabled    : ucr+ 
 Deassertions Enabled  : ucr+ 

Sensor ID              : PSU2_IN-POWER (0x40)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Threshold)  : Other (0x0b)
 Sensor Reading        : 60 (+/- 0) Watts
 Status                : ok
 Upper critical        : 2000.000
 Positive Hysteresis   : 10.000
 Negative Hysteresis   : 10.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : ucr 
 Settable Thresholds   : ucr 
 Assertion Events      : 
 Assertions Enabled    : ucr+ 
 Deassertions Enabled  : ucr+ 

Sensor ID              : PSU2_OUT-POWER (0x41)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Threshold)  : Other (0x0b)
 Sensor Reading        : 40 (+/- 0) Watts
 Status                : ok
 Upper critical        : 2000.000
 Positive Hysteresis   : 10.000
 Negative Hysteresis   : 10.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : ucr 
 Settable Thresholds   : ucr 
 Assertion Events      : 
 Assertions Enabled    : ucr+ 
 Deassertions Enabled  : ucr+ 

Sensor ID              : PSU2_FAN-SPEED (0x42)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Threshold)  : Fan (0x04)
 Sensor Reading        : 1650 (+/- 0) RPM
 Status                : ok
 Lower critical        : 450.000
 Positive Hysteresis   : 150.000
 Negative Hysteresis   : 150.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr 
 Settable Thresholds   : lcr 
 Assertion Events      : 
 Assertions Enabled    : lcr- 
 Deassertions Enabled  : lcr- 


------------  /usr/bin/ipmitool sdr elist ----------------

BMC_HEALTH       | 01h | ok  |  7.0 | 
VERSION_CHANGE   | 02h | ok  |  7.0 | 
BMC_WATCHDOG     | 03h | ok  |  7.0 | 
ACPI_STATE       | 04h | ok  |  7.0 | S0/G0: working
PROC_STATE       | 05h | ok  |  3.0 | 
SYSTEM_RESET     | 06h | ok  |  7.0 | System Restart
FW_PROGRESS      | 07h | ok  |  7.0 | 
PCIE_CR_INT      | 08h | ok  | 49.0 | 
INTEGRITY        | 0Ch | ok  |  7.0 | 
BIOS_POST        | 0Dh | ok  | 34.0 | 
BOARD-POWER      | 0Eh | ok  |  7.0 | 80 Watts
PAY_12-VOL       | 0Fh | ok  | 20.0 | 12 Volts
PAY_5_0-VOL      | 10h | ok  | 20.0 | 5.07 Volts
PAY_5_0_SB-VOL   | 11h | ok  | 20.0 | 5.04 Volts
PAY_3_3-VOL      | 12h | ok  | 20.0 | 3.30 Volts
PAY_3_3_SB-VOL   | 13h | ok  | 20.0 | 3.30 Volts
BAT_3_0-VOL      | 14h | ok  | 20.0 | 3.11 Volts
PCH_1_8_SB-VOL   | 15h | ok  | 20.0 | 1.81 Volts
CPU_VCCIN-VOL    | 16h | ok  | 20.0 | 1.78 Volts
PVDDQ_ABC-VOL    | 17h | ok  | 20.0 | 1.22 Volts
PVDDQ_DEF-VOL    | 18h | ok  | 20.0 | 1.22 Volts
BMC_1_15_SB-VOL  | 19h | ok  | 20.0 | 1.16 Volts
PCH_1_05_SB-VOL  | 1Ah | ok  | 20.0 | 1.06 Volts
CPU_VCCIO-VOL    | 1Bh | ok  | 20.0 | 1.02 Volts
PCH_VNN_SB-VOL   | 1Ch | ok  | 20.0 | 1.01 Volts
CPU_VCCSA-VOL    | 1Dh | ok  | 20.0 | 0.90 Volts
INLET-TMP        | 1Eh | ok  | 55.0 | 32 degrees C
OUTLET-TMP       | 1Fh | ok  |  7.0 | 49 degrees C
CPU-TMP          | 20h | ok  |  3.0 | 63 degrees C
HWM-TMP          | 21h | ok  |  7.0 | 36 degrees C
PCH-TMP          | 22h | ok  |  7.0 | 65 degrees C
CPU-DIMMA_1-TMP  | 23h | ok  | 32.0 | 37 degrees C
CPU-DIMMB_1-TMP  | 24h | ok  | 32.0 | 35 degrees C
CPU-DIMMD_1-TMP  | 25h | ok  | 32.0 | 37 degrees C
CPU-DIMME_1-TMP  | 26h | ok  | 32.0 | 36 degrees C
FAN1-SPEED       | 27h | ok  | 29.0 | 5900 RPM
FAN2-SPEED       | 28h | ok  | 29.0 | 5900 RPM
FAN3-SPEED       | 29h | ok  | 29.0 | 5900 RPM
PSU1             | 2Dh | ok  | 10.0 | Presence detected
PSU2             | 2Eh | ok  | 10.1 | Presence detected
PSU1_INTAKE-TMP  | 30h | ok  | 10.0 | 42 degrees C
PSU1_HOTSPOT-TMP | 31h | ok  | 10.0 | 44 degrees C
PSU1_IN-VOL      | 32h | ok  | 10.0 | 240 Volts
PSU1_OUT-VOL     | 33h | ok  | 10.0 | 12.10 Volts
PSU1_IN-CUR      | 34h | ok  | 10.0 | 0.25 Amps
PSU1_OUT-CUR     | 35h | ok  | 10.0 | 3 Amps
PSU1_IN-POWER    | 36h | ok  | 10.0 | 60 Watts
PSU1_OUT-POWER   | 37h | ok  | 10.0 | 30 Watts
PSU1_FAN-SPEED   | 38h | ok  | 10.0 | 1950 RPM
PSU2_INTAKE-TMP  | 3Ah | ok  | 10.1 | 37 degrees C
PSU2_HOTSPOT-TMP | 3Bh | ok  | 10.1 | 36 degrees C
PSU2_IN-VOL      | 3Ch | ok  | 10.1 | 238 Volts
PSU2_OUT-VOL     | 3Dh | ok  | 10.1 | 12.10 Volts
PSU2_IN-CUR      | 3Eh | ok  | 10.1 | 0.25 Amps
PSU2_OUT-CUR     | 3Fh | ok  | 10.1 | 3 Amps
PSU2_IN-POWER    | 40h | ok  | 10.1 | 60 Watts
PSU2_OUT-POWER   | 41h | ok  | 10.1 | 40 Watts
PSU2_FAN-SPEED   | 42h | ok  | 10.1 | 1650 RPM

------------  /usr/bin/ipmitool sdr elist -v ----------------

Running Get PICMG Properties my_addr 0x20, transit 0, target 0
Error response 0xc1 from Get PICMG Properities
Running Get VSO Capabilities my_addr 0x20, transit 0, target 0
Invalid completion code received: Invalid command
Discovered IPMB address 0x0
Sensor ID              : BMC_HEALTH (0x1)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Discrete): Management Subsys Health (0x28)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 Assertions Enabled    : Management Subsys Health
                         [Sensor failure]
 Deassertions Enabled  : Management Subsys Health
                         [Sensor failure]
 OEM                   : 0

Sensor ID              : VERSION_CHANGE (0x2)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Discrete): Version Change (0x2b)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 Assertions Enabled    : Version Change
 Deassertions Enabled  : Version Change
 OEM                   : 0

Sensor ID              : BMC_WATCHDOG (0x3)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Discrete): Watchdog2 (0x23)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 Assertions Enabled    : Watchdog2
                         [Timer expired]
                         [Hard reset]
                         [Power down]
                         [Power cycle]
 Deassertions Enabled  : Watchdog2
                         [Timer expired]
                         [Hard reset]
                         [Power down]
                         [Power cycle]
 OEM                   : 0

Sensor ID              : ACPI_STATE (0x4)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Discrete): System ACPI Power State (0x22)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 States Asserted       : System ACPI Power State
                         [S0/G0: working]
 Assertions Enabled    : System ACPI Power State
                         [S0/G0: working]
                         [S3: sleeping, processor & hw context lost, memory retained]
                         [S4: non-volatile sleep/suspend-to-disk]
                         [S5/G2: soft-off]
                         [G3: mechanical off]
 Deassertions Enabled  : System ACPI Power State
                         [S0/G0: working]
                         [S3: sleeping, processor & hw context lost, memory retained]
                         [S4: non-volatile sleep/suspend-to-disk]
                         [S5/G2: soft-off]
                         [G3: mechanical off]
 OEM                   : 0

Sensor ID              : PROC_STATE (0x5)
 Entity ID             : 3.0 (Processor)
 Sensor Type (Discrete): Processor (0x07)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 Assertions Enabled    : Processor
                         [IERR]
                         [Thermal Trip]
                         [FRB2/Hang in POST failure]
                         [Throttled]
                         [Uncorrectable machine check exception]
                         [Correctable machine check error]
 Deassertions Enabled  : Processor
                         [IERR]
                         [Thermal Trip]
                         [FRB2/Hang in POST failure]
                         [Throttled]
                         [Uncorrectable machine check exception]
                         [Correctable machine check error]
 OEM                   : 0

Sensor ID              : SYSTEM_RESET (0x6)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Discrete): System Boot Initiated (0x1d)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 States Asserted       : System Boot Initiated
                         [System Restart]
 Assertions Enabled    : System Boot Initiated
                         [Initiated by power up]
                         [Initiated by hard reset]
                         [System Restart]
 Deassertions Enabled  : System Boot Initiated
                         [Initiated by power up]
                         [Initiated by hard reset]
                         [System Restart]
 OEM                   : 0

Sensor ID              : FW_PROGRESS (0x7)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Discrete): System Firmwares (0x0f)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 Assertions Enabled    : System Firmwares
                         [Unknown Error]
                         [Unknown Hang]
                         [Unknown Progress]
 Deassertions Enabled  : System Firmwares
                         [Unknown Error]
                         [Unknown Hang]
                         [Unknown Progress]
 OEM                   : 0

Sensor ID              : PCIE_CR_INT (0x8)
 Entity ID             : 49.0 (PCI Express Bus)
 Sensor Type (Discrete): Critical Interrupt (0x13)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 Assertions Enabled    : Critical Interrupt
                         [NMI/Diag Interrupt]
                         [I/O Channel check NMI]
                         [PCI PERR]
 Deassertions Enabled  : Critical Interrupt
                         [NMI/Diag Interrupt]
                         [I/O Channel check NMI]
                         [PCI PERR]
 OEM                   : 0

Sensor ID              : INTEGRITY (0xc)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Discrete): Unknown (0xc0)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 OEM                   : C0

Sensor ID              : BIOS_POST (0xd)
 Entity ID             : 34.0 (BIOS)
 Sensor Type (Discrete): System Firmwares (0x0f)
 Sensor Reading        : 0h
 Event Message Control : No Events From Sensor
 Event Status          : Event Messages Disabled
 Event Enable          : Event Messages Disabled
 OEM                   : 0

Sensor ID              : BOARD-POWER (0xe)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Threshold)  : Other (0x0b)
 Sensor Reading        : 80 (+/- 0) Watts
 Status                : ok
 Positive Hysteresis   : Unspecified
 Negative Hysteresis   : Unspecified
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : 
 Settable Thresholds   : 
 Assertion Events      : 
 Assertions Enabled    : 

Sensor ID              : PAY_12-VOL (0xf)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 12 (+/- 0) Volts
 Status                : ok
 Upper critical        : 13.248
 Lower critical        : 10.752
 Positive Hysteresis   : 0.288
 Negative Hysteresis   : 0.288
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PAY_5_0-VOL (0x10)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 5.072 (+/- 0) Volts
 Status                : ok
 Upper critical        : 5.361
 Lower critical        : 4.655
 Positive Hysteresis   : 0.096
 Negative Hysteresis   : 0.096
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PAY_5_0_SB-VOL (0x11)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 5.040 (+/- 0) Volts
 Status                : ok
 Upper critical        : 5.361
 Lower critical        : 4.655
 Positive Hysteresis   : 0.096
 Negative Hysteresis   : 0.096
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PAY_3_3-VOL (0x12)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 3.302 (+/- 0) Volts
 Status                : ok
 Upper critical        : 3.519
 Lower critical        : 3.061
 Positive Hysteresis   : 0.072
 Negative Hysteresis   : 0.072
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PAY_3_3_SB-VOL (0x13)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 3.302 (+/- 0) Volts
 Status                : ok
 Upper critical        : 3.519
 Lower critical        : 3.061
 Positive Hysteresis   : 0.072
 Negative Hysteresis   : 0.072
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : BAT_3_0-VOL (0x14)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 3.109 (+/- 0) Volts
 Status                : ok
 Upper critical        : 3.254
 Lower critical        : 1.928
 Positive Hysteresis   : 0.072
 Negative Hysteresis   : 0.072
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PCH_1_8_SB-VOL (0x15)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 1.808 (+/- 0) Volts
 Status                : ok
 Upper critical        : 1.880
 Lower critical        : 1.712
 Positive Hysteresis   : 0.032
 Negative Hysteresis   : 0.032
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : CPU_VCCIN-VOL (0x16)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 1.784 (+/- 0) Volts
 Status                : ok
 Upper critical        : 2.040
 Lower critical        : 1.448
 Positive Hysteresis   : 0.032
 Negative Hysteresis   : 0.032
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PVDDQ_ABC-VOL (0x17)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 1.224 (+/- 0) Volts
 Status                : ok
 Upper critical        : 1.304
 Lower critical        : 1.112
 Positive Hysteresis   : 0.024
 Negative Hysteresis   : 0.024
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PVDDQ_DEF-VOL (0x18)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 1.216 (+/- 0) Volts
 Status                : ok
 Upper critical        : 1.304
 Lower critical        : 1.112
 Positive Hysteresis   : 0.024
 Negative Hysteresis   : 0.024
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : BMC_1_15_SB-VOL (0x19)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 1.157 (+/- 0) Volts
 Status                : ok
 Upper critical        : 1.257
 Lower critical        : 1.044
 Positive Hysteresis   : 0.014
 Negative Hysteresis   : 0.014
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PCH_1_05_SB-VOL (0x1a)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 1.064 (+/- 0) Volts
 Status                : ok
 Upper critical        : 1.136
 Lower critical        : 0.960
 Positive Hysteresis   : 0.016
 Negative Hysteresis   : 0.016
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : CPU_VCCIO-VOL (0x1b)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 1.016 (+/- 0) Volts
 Status                : ok
 Upper critical        : 1.096
 Lower critical        : 0.904
 Positive Hysteresis   : 0.016
 Negative Hysteresis   : 0.016
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PCH_VNN_SB-VOL (0x1c)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 1.008 (+/- 0) Volts
 Status                : ok
 Upper critical        : 1.096
 Lower critical        : 0.904
 Positive Hysteresis   : 0.016
 Negative Hysteresis   : 0.016
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : CPU_VCCSA-VOL (0x1d)
 Entity ID             : 20.0 (Power Module)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 0.896 (+/- 0) Volts
 Status                : ok
 Upper critical        : 1.152
 Lower critical        : 0.456
 Positive Hysteresis   : 0.024
 Negative Hysteresis   : 0.024
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : INLET-TMP (0x1e)
 Entity ID             : 55.0 (Air Inlet)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 32 (+/- 0) degrees C
 Status                : ok
 Upper non-recoverable : 100.000
 Upper critical        : 75.000
 Upper non-critical    : 60.000
 Positive Hysteresis   : 3.000
 Negative Hysteresis   : 3.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr unr 
 Settable Thresholds   : unc ucr unr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ unr+ 
 Deassertions Enabled  : unc+ ucr+ unr+ 

Sensor ID              : OUTLET-TMP (0x1f)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 49 (+/- 0) degrees C
 Status                : ok
 Upper critical        : 75.000
 Upper non-critical    : 65.000
 Positive Hysteresis   : 3.000
 Negative Hysteresis   : 3.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr 
 Settable Thresholds   : unc ucr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ 
 Deassertions Enabled  : unc+ ucr+ 

Sensor ID              : CPU-TMP (0x20)
 Entity ID             : 3.0 (Processor)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 63 (+/- 0) degrees C
 Status                : ok
 Upper critical        : 105.000
 Upper non-critical    : 90.000
 Positive Hysteresis   : 3.000
 Negative Hysteresis   : 3.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr 
 Settable Thresholds   : unc ucr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ 
 Deassertions Enabled  : unc+ ucr+ 

Sensor ID              : HWM-TMP (0x21)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 36 (+/- 0) degrees C
 Status                : ok
 Upper non-recoverable : 80.000
 Upper critical        : 70.000
 Upper non-critical    : 60.000
 Positive Hysteresis   : 3.000
 Negative Hysteresis   : 3.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr unr 
 Settable Thresholds   : unc ucr unr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ unr+ 
 Deassertions Enabled  : unc+ ucr+ unr+ 

Sensor ID              : PCH-TMP (0x22)
 Entity ID             : 7.0 (System Board)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 65 (+/- 0) degrees C
 Status                : ok
 Upper critical        : 100.000
 Upper non-critical    : 90.000
 Positive Hysteresis   : 3.000
 Negative Hysteresis   : 3.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr 
 Settable Thresholds   : unc ucr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ 
 Deassertions Enabled  : unc+ ucr+ 

Sensor ID              : CPU-DIMMA_1-TMP (0x23)
 Entity ID             : 32.0 (Memory Device)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 37 (+/- 0) degrees C
 Status                : ok
 Upper critical        : 95.000
 Upper non-critical    : 85.000
 Positive Hysteresis   : 3.000
 Negative Hysteresis   : 3.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr 
 Settable Thresholds   : unc ucr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ 
 Deassertions Enabled  : unc+ ucr+ 

Sensor ID              : CPU-DIMMB_1-TMP (0x24)
 Entity ID             : 32.0 (Memory Device)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 35 (+/- 0) degrees C
 Status                : ok
 Upper critical        : 95.000
 Upper non-critical    : 85.000
 Positive Hysteresis   : 3.000
 Negative Hysteresis   : 3.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr 
 Settable Thresholds   : unc ucr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ 
 Deassertions Enabled  : unc+ ucr+ 

Sensor ID              : CPU-DIMMD_1-TMP (0x25)
 Entity ID             : 32.0 (Memory Device)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 37 (+/- 0) degrees C
 Status                : ok
 Upper critical        : 95.000
 Upper non-critical    : 85.000
 Positive Hysteresis   : 3.000
 Negative Hysteresis   : 3.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr 
 Settable Thresholds   : unc ucr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ 
 Deassertions Enabled  : unc+ ucr+ 

Sensor ID              : CPU-DIMME_1-TMP (0x26)
 Entity ID             : 32.0 (Memory Device)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 36 (+/- 0) degrees C
 Status                : ok
 Upper critical        : 95.000
 Upper non-critical    : 85.000
 Positive Hysteresis   : 3.000
 Negative Hysteresis   : 3.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr 
 Settable Thresholds   : unc ucr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ 
 Deassertions Enabled  : unc+ ucr+ 

Sensor ID              : FAN1-SPEED (0x27)
 Entity ID             : 29.0 (Fan Device)
 Sensor Type (Threshold)  : Fan (0x04)
 Sensor Reading        : 5900 (+/- 0) RPM
 Status                : ok
 Lower critical        : 1200.000
 Positive Hysteresis   : 100.000
 Negative Hysteresis   : 100.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr 
 Settable Thresholds   : lcr 
 Assertion Events      : 
 Assertions Enabled    : lcr- 
 Deassertions Enabled  : lcr- 

Sensor ID              : FAN2-SPEED (0x28)
 Entity ID             : 29.0 (Fan Device)
 Sensor Type (Threshold)  : Fan (0x04)
 Sensor Reading        : 5900 (+/- 0) RPM
 Status                : ok
 Lower critical        : 1200.000
 Positive Hysteresis   : 100.000
 Negative Hysteresis   : 100.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr 
 Settable Thresholds   : lcr 
 Assertion Events      : 
 Assertions Enabled    : lcr- 
 Deassertions Enabled  : lcr- 

Sensor ID              : FAN3-SPEED (0x29)
 Entity ID             : 29.0 (Fan Device)
 Sensor Type (Threshold)  : Fan (0x04)
 Sensor Reading        : 5900 (+/- 0) RPM
 Status                : ok
 Lower critical        : 1200.000
 Positive Hysteresis   : 100.000
 Negative Hysteresis   : 100.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr 
 Settable Thresholds   : lcr 
 Assertion Events      : 
 Assertions Enabled    : lcr- 
 Deassertions Enabled  : lcr- 

Sensor ID              : PSU1 (0x2d)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Discrete): Power Supply (0x08)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 States Asserted       : Power Supply
                         [Presence detected]
 Assertions Enabled    : Power Supply
                         [Presence detected]
                         [Failure detected]
                         [Predictive failure]
                         [Power Supply AC lost]
 Deassertions Enabled  : Power Supply
                         [Presence detected]
                         [Failure detected]
                         [Predictive failure]
                         [Power Supply AC lost]
 OEM                   : 0

Sensor ID              : PSU2 (0x2e)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Discrete): Power Supply (0x08)
 Sensor Reading        : 0h
 Event Message Control : Per-threshold
 States Asserted       : Power Supply
                         [Presence detected]
 Assertions Enabled    : Power Supply
                         [Presence detected]
                         [Failure detected]
                         [Predictive failure]
                         [Power Supply AC lost]
 Deassertions Enabled  : Power Supply
                         [Presence detected]
                         [Failure detected]
                         [Predictive failure]
                         [Power Supply AC lost]
 OEM                   : 0

Sensor ID              : PSU1_INTAKE-TMP (0x30)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 42 (+/- 0) degrees C
 Status                : ok
 Upper non-recoverable : 85.000
 Upper critical        : 75.000
 Upper non-critical    : 65.000
 Positive Hysteresis   : Unspecified
 Negative Hysteresis   : Unspecified
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr unr 
 Settable Thresholds   : unc ucr unr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ unr+ 
 Deassertions Enabled  : unc+ ucr+ unr+ 

Sensor ID              : PSU1_HOTSPOT-TMP (0x31)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 44 (+/- 0) degrees C
 Status                : ok
 Upper non-recoverable : 110.000
 Upper critical        : 100.000
 Upper non-critical    : 90.000
 Positive Hysteresis   : Unspecified
 Negative Hysteresis   : Unspecified
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr unr 
 Settable Thresholds   : unc ucr unr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ unr+ 
 Deassertions Enabled  : unc+ ucr+ unr+ 

Sensor ID              : PSU1_IN-VOL (0x32)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 240 (+/- 0) Volts
 Status                : ok
 Upper critical        : 264.000
 Lower critical        : 90.000
 Positive Hysteresis   : 2.000
 Negative Hysteresis   : 2.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PSU1_OUT-VOL (0x33)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 12.100 (+/- 0) Volts
 Status                : ok
 Upper critical        : 12.800
 Lower critical        : 11.500
 Positive Hysteresis   : 0.100
 Negative Hysteresis   : 0.100
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PSU1_IN-CUR (0x34)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Threshold)  : Current (0x03)
 Sensor Reading        : 0.250 (+/- 0) Amps
 Status                : ok
 Upper critical        : 18.000
 Positive Hysteresis   : 0.250
 Negative Hysteresis   : 0.250
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : ucr 
 Settable Thresholds   : ucr 
 Assertion Events      : 
 Assertions Enabled    : ucr+ 
 Deassertions Enabled  : ucr+ 

Sensor ID              : PSU1_OUT-CUR (0x35)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Threshold)  : Current (0x03)
 Sensor Reading        : 3 (+/- 0) Amps
 Status                : ok
 Upper critical        : 166.000
 Positive Hysteresis   : 1.000
 Negative Hysteresis   : 1.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : ucr 
 Settable Thresholds   : ucr 
 Assertion Events      : 
 Assertions Enabled    : ucr+ 
 Deassertions Enabled  : ucr+ 

Sensor ID              : PSU1_IN-POWER (0x36)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Threshold)  : Other (0x0b)
 Sensor Reading        : 60 (+/- 0) Watts
 Status                : ok
 Upper critical        : 2000.000
 Positive Hysteresis   : 10.000
 Negative Hysteresis   : 10.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : ucr 
 Settable Thresholds   : ucr 
 Assertion Events      : 
 Assertions Enabled    : ucr+ 
 Deassertions Enabled  : ucr+ 

Sensor ID              : PSU1_OUT-POWER (0x37)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Threshold)  : Other (0x0b)
 Sensor Reading        : 30 (+/- 0) Watts
 Status                : ok
 Upper critical        : 2000.000
 Positive Hysteresis   : 10.000
 Negative Hysteresis   : 10.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : ucr 
 Settable Thresholds   : ucr 
 Assertion Events      : 
 Assertions Enabled    : ucr+ 
 Deassertions Enabled  : ucr+ 

Sensor ID              : PSU1_FAN-SPEED (0x38)
 Entity ID             : 10.0 (Power Supply)
 Sensor Type (Threshold)  : Fan (0x04)
 Sensor Reading        : 2100 (+/- 0) RPM
 Status                : ok
 Lower critical        : 450.000
 Positive Hysteresis   : 150.000
 Negative Hysteresis   : 150.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr 
 Settable Thresholds   : lcr 
 Assertion Events      : 
 Assertions Enabled    : lcr- 
 Deassertions Enabled  : lcr- 

Sensor ID              : PSU2_INTAKE-TMP (0x3a)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 37 (+/- 0) degrees C
 Status                : ok
 Upper non-recoverable : 85.000
 Upper critical        : 75.000
 Upper non-critical    : 65.000
 Positive Hysteresis   : Unspecified
 Negative Hysteresis   : Unspecified
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr unr 
 Settable Thresholds   : unc ucr unr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ unr+ 
 Deassertions Enabled  : unc+ ucr+ unr+ 

Sensor ID              : PSU2_HOTSPOT-TMP (0x3b)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Threshold)  : Temperature (0x01)
 Sensor Reading        : 36 (+/- 0) degrees C
 Status                : ok
 Upper non-recoverable : 110.000
 Upper critical        : 100.000
 Upper non-critical    : 90.000
 Positive Hysteresis   : Unspecified
 Negative Hysteresis   : Unspecified
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : unc ucr unr 
 Settable Thresholds   : unc ucr unr 
 Assertion Events      : 
 Assertions Enabled    : unc+ ucr+ unr+ 
 Deassertions Enabled  : unc+ ucr+ unr+ 

Sensor ID              : PSU2_IN-VOL (0x3c)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 238 (+/- 0) Volts
 Status                : ok
 Upper critical        : 264.000
 Lower critical        : 90.000
 Positive Hysteresis   : 2.000
 Negative Hysteresis   : 2.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PSU2_OUT-VOL (0x3d)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Threshold)  : Voltage (0x02)
 Sensor Reading        : 12.100 (+/- 0) Volts
 Status                : ok
 Upper critical        : 12.800
 Lower critical        : 11.500
 Positive Hysteresis   : 0.100
 Negative Hysteresis   : 0.100
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr ucr 
 Settable Thresholds   : lcr ucr 
 Assertion Events      : 
 Assertions Enabled    : lcr- ucr+ 
 Deassertions Enabled  : lcr- ucr+ 

Sensor ID              : PSU2_IN-CUR (0x3e)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Threshold)  : Current (0x03)
 Sensor Reading        : 0.250 (+/- 0) Amps
 Status                : ok
 Upper critical        : 18.000
 Positive Hysteresis   : 0.250
 Negative Hysteresis   : 0.250
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : ucr 
 Settable Thresholds   : ucr 
 Assertion Events      : 
 Assertions Enabled    : ucr+ 
 Deassertions Enabled  : ucr+ 

Sensor ID              : PSU2_OUT-CUR (0x3f)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Threshold)  : Current (0x03)
 Sensor Reading        : 4 (+/- 0) Amps
 Status                : ok
 Upper critical        : 166.000
 Positive Hysteresis   : 1.000
 Negative Hysteresis   : 1.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : ucr 
 Settable Thresholds   : ucr 
 Assertion Events      : 
 Assertions Enabled    : ucr+ 
 Deassertions Enabled  : ucr+ 

Sensor ID              : PSU2_IN-POWER (0x40)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Threshold)  : Other (0x0b)
 Sensor Reading        : 60 (+/- 0) Watts
 Status                : ok
 Upper critical        : 2000.000
 Positive Hysteresis   : 10.000
 Negative Hysteresis   : 10.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : ucr 
 Settable Thresholds   : ucr 
 Assertion Events      : 
 Assertions Enabled    : ucr+ 
 Deassertions Enabled  : ucr+ 

Sensor ID              : PSU2_OUT-POWER (0x41)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Threshold)  : Other (0x0b)
 Sensor Reading        : 40 (+/- 0) Watts
 Status                : ok
 Upper critical        : 2000.000
 Positive Hysteresis   : 10.000
 Negative Hysteresis   : 10.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : ucr 
 Settable Thresholds   : ucr 
 Assertion Events      : 
 Assertions Enabled    : ucr+ 
 Deassertions Enabled  : ucr+ 

Sensor ID              : PSU2_FAN-SPEED (0x42)
 Entity ID             : 10.1 (Power Supply)
 Sensor Type (Threshold)  : Fan (0x04)
 Sensor Reading        : 1650 (+/- 0) RPM
 Status                : ok
 Lower critical        : 450.000
 Positive Hysteresis   : 150.000
 Negative Hysteresis   : 150.000
 Minimum sensor range  : Unspecified
 Maximum sensor range  : Unspecified
 Event Message Control : Per-threshold
 Readable Thresholds   : lcr 
 Settable Thresholds   : lcr 
 Assertion Events      : 
 Assertions Enabled    : lcr- 
 Deassertions Enabled  : lcr- 


------------  /usr/bin/ipmitool sensor ----------------

BMC_HEALTH       | 0x0        | discrete   | 0x0000| na        | na        | na        | na        | na        | na        
VERSION_CHANGE   | 0x0        | discrete   | 0x0000| na        | na        | na        | na        | na        | na        
BMC_WATCHDOG     | 0x0        | discrete   | 0x0000| na        | na        | na        | na        | na        | na        
ACPI_STATE       | 0x0        | discrete   | 0x0100| na        | na        | na        | na        | na        | na        
PROC_STATE       | 0x0        | discrete   | 0x0000| na        | na        | na        | na        | na        | na        
SYSTEM_RESET     | 0x0        | discrete   | 0x8000| na        | na        | na        | na        | na        | na        
FW_PROGRESS      | 0x0        | discrete   | 0x0000| na        | na        | na        | na        | na        | na        
PCIE_CR_INT      | 0x0        | discrete   | 0x0000| na        | na        | na        | na        | na        | na        
INTEGRITY        | 0x0        | discrete   | 0x0000| na        | na        | na        | na        | na        | na        
BIOS_POST        | 0x0        | discrete   | 0x0000| na        | na        | na        | na        | na        | na        
BOARD-POWER      | 70.000     | Watts      | ok    | na        | na        | na        | na        | na        | na        
PAY_12-VOL       | 12.000     | Volts      | ok    | na        | 10.752    | na        | na        | 13.248    | na        
PAY_5_0-VOL      | 5.072      | Volts      | ok    | na        | 4.655     | na        | na        | 5.361     | na        
PAY_5_0_SB-VOL   | 5.040      | Volts      | ok    | na        | 4.655     | na        | na        | 5.361     | na        
PAY_3_3-VOL      | 3.302      | Volts      | ok    | na        | 3.061     | na        | na        | 3.519     | na        
PAY_3_3_SB-VOL   | 3.302      | Volts      | ok    | na        | 3.061     | na        | na        | 3.519     | na        
BAT_3_0-VOL      | 3.109      | Volts      | ok    | na        | 1.928     | na        | na        | 3.254     | na        
PCH_1_8_SB-VOL   | 1.808      | Volts      | ok    | na        | 1.712     | na        | na        | 1.880     | na        
CPU_VCCIN-VOL    | 1.784      | Volts      | ok    | na        | 1.448     | na        | na        | 2.040     | na        
PVDDQ_ABC-VOL    | 1.224      | Volts      | ok    | na        | 1.112     | na        | na        | 1.304     | na        
PVDDQ_DEF-VOL    | 1.216      | Volts      | ok    | na        | 1.112     | na        | na        | 1.304     | na        
BMC_1_15_SB-VOL  | 1.157      | Volts      | ok    | na        | 1.044     | na        | na        | 1.257     | na        
PCH_1_05_SB-VOL  | 1.064      | Volts      | ok    | na        | 0.960     | na        | na        | 1.136     | na        
CPU_VCCIO-VOL    | 1.016      | Volts      | ok    | na        | 0.904     | na        | na        | 1.096     | na        
PCH_VNN_SB-VOL   | 1.008      | Volts      | ok    | na        | 0.904     | na        | na        | 1.096     | na        
CPU_VCCSA-VOL    | 0.896      | Volts      | ok    | na        | 0.456     | na        | na        | 1.152     | na        
INLET-TMP        | 32.000     | degrees C  | ok    | na        | na        | na        | 60.000    | 75.000    | 100.000   
OUTLET-TMP       | 49.000     | degrees C  | ok    | na        | na        | na        | 65.000    | 75.000    | na        
CPU-TMP          | 63.000     | degrees C  | ok    | na        | na        | na        | 90.000    | 105.000   | na        
HWM-TMP          | 36.000     | degrees C  | ok    | na        | na        | na        | 60.000    | 70.000    | 80.000    
PCH-TMP          | 65.000     | degrees C  | ok    | na        | na        | na        | 90.000    | 100.000   | na        
CPU-DIMMA_1-TMP  | 37.000     | degrees C  | ok    | na        | na        | na        | 85.000    | 95.000    | na        
CPU-DIMMB_1-TMP  | 35.000     | degrees C  | ok    | na        | na        | na        | 85.000    | 95.000    | na        
CPU-DIMMD_1-TMP  | 37.000     | degrees C  | ok    | na        | na        | na        | 85.000    | 95.000    | na        
CPU-DIMME_1-TMP  | 36.000     | degrees C  | ok    | na        | na        | na        | 85.000    | 95.000    | na        
FAN1-SPEED       | 5900.000   | RPM        | ok    | na        | 1200.000  | na        | na        | na        | na        
FAN2-SPEED       | 5900.000   | RPM        | ok    | na        | 1200.000  | na        | na        | na        | na        
FAN3-SPEED       | 5900.000   | RPM        | ok    | na        | 1200.000  | na        | na        | na        | na        
PSU1             | 0x0        | discrete   | 0x0100| na        | na        | na        | na        | na        | na        
PSU2             | 0x0        | discrete   | 0x0100| na        | na        | na        | na        | na        | na        
PSU1_INTAKE-TMP  | 42.000     | degrees C  | ok    | na        | na        | na        | 65.000    | 75.000    | 85.000    
PSU1_HOTSPOT-TMP | 44.000     | degrees C  | ok    | na        | na        | na        | 90.000    | 100.000   | 110.000   
PSU1_IN-VOL      | 240.000    | Volts      | ok    | na        | 90.000    | na        | na        | 264.000   | na        
PSU1_OUT-VOL     | 12.100     | Volts      | ok    | na        | 11.500    | na        | na        | 12.800    | na        
PSU1_IN-CUR      | 0.250      | Amps       | ok    | na        | na        | na        | na        | 18.000    | na        
PSU1_OUT-CUR     | 3.000      | Amps       | ok    | na        | na        | na        | na        | 166.000   | na        
PSU1_IN-POWER    | 60.000     | Watts      | ok    | na        | na        | na        | na        | 2000.000  | na        
PSU1_OUT-POWER   | 30.000     | Watts      | ok    | na        | na        | na        | na        | 2000.000  | na        
PSU1_FAN-SPEED   | 2100.000   | RPM        | ok    | na        | 450.000   | na        | na        | na        | na        
PSU2_INTAKE-TMP  | 37.000     | degrees C  | ok    | na        | na        | na        | 65.000    | 75.000    | 85.000    
PSU2_HOTSPOT-TMP | 36.000     | degrees C  | ok    | na        | na        | na        | 90.000    | 100.000   | 110.000   
PSU2_IN-VOL      | 238.000    | Volts      | ok    | na        | 90.000    | na        | na        | 264.000   | na        
PSU2_OUT-VOL     | 12.100     | Volts      | ok    | na        | 11.500    | na        | na        | 12.800    | na        
PSU2_IN-CUR      | 0.250      | Amps       | ok    | na        | na        | na        | na        | 18.000    | na        
PSU2_OUT-CUR     | 4.000      | Amps       | ok    | na        | na        | na        | na        | 166.000   | na        
PSU2_IN-POWER    | 60.000     | Watts      | ok    | na        | na        | na        | na        | 2000.000  | na        
PSU2_OUT-POWER   | 40.000     | Watts      | ok    | na        | na        | na        | na        | 2000.000  | na        
PSU2_FAN-SPEED   | 1650.000   | RPM        | ok    | na        | 450.000   | na        | na        | na        | na        

------------  /usr/bin/ipmitool fru print ----------------

FRU Device Description : Builtin FRU Device (ID 0)
 Chassis Type          : Rack Mount Chassis
 Chassis Part Number   : FWA-3050
 Chassis Serial        : GSAC421170
 Board Mfg Date        : Sat Oct 11 13:16:00 2025
 Board Mfg             : Advantech
 Board Product         : NAMB-3050
 Board Serial          : AKKC563890
 Board Part Number     : 969230500D2
 Product Manufacturer  : Advantech
 Product Name          : Silver Peak Systems
 Product Part Number   : FWA-ASP3050-4CA4RU
 Product Version       : Rev 1
 Product Serial        : GSAC421170
 Product Asset Tag     : 201683-001 Rev B

FRU Device Description : PSU1-FRU (ID 2)
 Product Manufacturer  : DELTA
 Product Name          : DPS-300AB-102 B
 Product Part Number   :           
 Product Version       : 00F
 Product Serial        : JLKD2537000405
 Product Extra         : 00

FRU Device Description : PSU2-FRU (ID 3)
 Product Manufacturer  : DELTA
 Product Name          : DPS-300AB-102 B
 Product Part Number   :           
 Product Version       : 00F
 Product Serial        : JLKD2537000404
 Product Extra         : 00


------------  /usr/bin/ipmitool fru print -v ----------------

Running Get PICMG Properties my_addr 0x20, transit 0, target 0
Error response 0xc1 from Get PICMG Properities
Running Get VSO Capabilities my_addr 0x20, transit 0, target 0
Invalid completion code received: Invalid command
Discovered IPMB address 0x0
Retrying FRU read with request size 25
Retrying FRU read with request size 25
Retrying FRU read with request size 25
FRU Device Description : Builtin FRU Device (ID 0)
 Chassis Type          : Rack Mount Chassis
 Chassis Part Number   : FWA-3050
 Chassis Serial        : GSAC421170
 Board Mfg Date        : Sat Oct 11 13:16:00 2025
 Board Mfg             : Advantech
 Board Product         : NAMB-3050
 Board Serial          : AKKC563890
 Board Part Number     : 969230500D2
 Board FRU ID          : fwa3050_fru_silverpeak_0.01.xml
 Product Manufacturer  : Advantech
 Product Name          : Silver Peak Systems
 Product Part Number   : FWA-ASP3050-4CA4RU
 Product Version       : Rev 1
 Product Serial        : GSAC421170
 Product Asset Tag     : 201683-001 Rev B
 Product FRU ID        : fwa3050_fru_silverpeak_0.01.xml
  OEM (Advantech) Record

FRU Device Description : PSU1-FRU (ID 2)
 Product Manufacturer  : DELTA
 Product Name          : DPS-300AB-102 B
 Product Part Number   :           
 Product Version       : 00F
 Product Serial        : JLKD2537000405
 Product Extra         : 00
 Power Supply Record
  Capacity                   : 300 W
  Peak VA                    : 354 VA
  Inrush Current             : 55 A
  Inrush Interval            : 5 ms
  Input Voltage Range 1      : 90-140 V
  Input Voltage Range 2      : 180-264 V
  Input Frequency Range      : 50-60 Hz
  A/C Dropout Tolerance      : 10 ms
  Flags                      : 'Predictive fail' 'Power factor correction' 'Autoswitch voltage' 'Hot swap' 'Two pulses per rotation'
  Peak capacity              : 354 W
  Peak capacity holdup       : 10 s
  Combined capacity          : not specified
  Fan lower threshold        : 13 RPS
 DC Output Record
  Output Number              : 1
  Standby power              : No
  Nominal voltage            : 12.00 V
  Max negative deviation     : 11.40 V
  Max positive deviation     : 12.60 V
  Ripple and noise pk-pk     : 120 mV
  Minimum current draw       : 0.000 A
  Maximum current draw       : 24.000 A
 DC Output Record
  Output Number              : 2
  Standby power              : Yes
  Nominal voltage            : 12.00 V
  Max negative deviation     : 11.40 V
  Max positive deviation     : 12.60 V
  Ripple and noise pk-pk     : 120 mV
  Minimum current draw       : 0.000 A
  Maximum current draw       : 1.500 A

FRU Device Description : PSU2-FRU (ID 3)
 Product Manufacturer  : DELTA
 Product Name          : DPS-300AB-102 B
 Product Part Number   :           
 Product Version       : 00F
 Product Serial        : JLKD2537000404
 Product Extra         : 00
 Power Supply Record
  Capacity                   : 300 W
  Peak VA                    : 354 VA
  Inrush Current             : 55 A
  Inrush Interval            : 5 ms
  Input Voltage Range 1      : 90-140 V
  Input Voltage Range 2      : 180-264 V
  Input Frequency Range      : 50-60 Hz
  A/C Dropout Tolerance      : 10 ms
  Flags                      : 'Predictive fail' 'Power factor correction' 'Autoswitch voltage' 'Hot swap' 'Two pulses per rotation'
  Peak capacity              : 354 W
  Peak capacity holdup       : 10 s
  Combined capacity          : not specified
  Fan lower threshold        : 13 RPS
 DC Output Record
  Output Number              : 1
  Standby power              : No
  Nominal voltage            : 12.00 V
  Max negative deviation     : 11.40 V
  Max positive deviation     : 12.60 V
  Ripple and noise pk-pk     : 120 mV
  Minimum current draw       : 0.000 A
  Maximum current draw       : 24.000 A
 DC Output Record
  Output Number              : 2
  Standby power              : Yes
  Nominal voltage            : 12.00 V
  Max negative deviation     : 11.40 V
  Max positive deviation     : 12.60 V
  Ripple and noise pk-pk     : 120 mV
  Minimum current draw       : 0.000 A
  Maximum current draw       : 1.500 A


------------  /usr/bin/ipmitool lan print ----------------

Get Channel Info command failed: Requested sensor, data, or record not found
Get Channel Info command failed: Requested sensor, data, or record not found
Get Channel Info command failed: Requested sensor, data, or record not found
Get Channel Info command failed: Requested sensor, data, or record not found
Get Channel Info command failed: Requested sensor, data, or record not found
Get Channel Info command failed: Requested sensor, data, or record not found
Get Channel Info command failed: Requested sensor, data, or record not found
Get Channel Info command failed: Requested sensor, data, or record not found
Get Channel Info command failed: Requested sensor, data, or record not found
Get Channel Info command failed: Requested sensor, data, or record not found
Invalid channel: 0

------------  /usr/bin/ipmitool sol info 1 ----------------

Info: SOL parameter 'Set In Progress (0)' not supported
Info: SOL parameter 'Enable (1)' not supported
Info: SOL parameter 'Authentication (2)' not supported
Info: SOL parameter 'Character Interval (3)' not supported
Info: SOL parameter 'Retry (4)' not supported
Info: SOL parameter 'Nonvolatile Bitrate (5)' not supported
Info: SOL parameter 'Volatile Bitrate (6)' not supported
Info: SOL parameter 'Payload Channel (7)' not supported - defaulting to 0x01
Info: SOL parameter 'Payload Port (8)' not supported - can't determine which payload port to use on NULL session

------------  /usr/bin/ipmitool hpm check ----------------


PICMG HPM.1 Upgrade Agent 1.0.9: 

-------Target Information-------
Device Id          : 0xbd
Device Revision    : 0x81
Product Id         : 0x3050
Manufacturer Id    : 0x2839 (Advantech)


--------------------------------------------------------------------------
|ID  | Name        |                     Versions                        |
|    |             |     Active      |     Backup      |      Deferred   |
--------------------------------------------------------------------------
|   0|3050 BL      |   1.00 00000000 | ---.-- -------- | ---.-- -------- |
|   1|3050 BMC     |   1.14 00000000 |   1.14 00000000 | ---.-- -------- |
|*  2|3050 BIOS    |   1.24 00000000 |   1.24 00000000 | ---.-- -------- |
|*  3|3050 NVRAM   |   6.00 00000000 | ---.-- -------- | ---.-- -------- |
--------------------------------------------------------------------------
(*) Component requires Payload Cold Reset